User Documentation
3 / 5
SPEC
custom
specic
SPEC
custom
specic
IN.LO OU.LOIN.HI OU.HI
-/+300 -/+10299 10.0300 10.0
9999
HZCURRCURR YESACTI
-/+200 -/+5298 9.99299 9.99
9998
KHZVOLTVOLT
NOPASV
-/+150 10-0
-/+100 5-0-299 -9.99-298 -9.99
0001
-/+20 0-10-300 -10.0-299 -10.0
0000
-/+10 2-10
-/+5 0-5
-/+1 1-5
-/+0.5
-/+0.1
300
200
100
0-60
0-30
0-10
2-10
SPEC
custom
specic
SPEC
custom
specic
IN.LO OU.LOIN.HI OU.HI
-/+100 -/+2099.9 20100 20
-/+50 -/+1099.8 19.999.9 19.9
-/+20 20-0
-/+10 20-4-99.9 -19.9-99.8 -19.9
-/+5 10-0-100 -20-99.9 -20
-/+1 0-20
-/+0.3 4-20
0-10
100
0-50
0-20
4-20
BWOUTIN E.PASMODE
N.PAS
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK OK
OK OK
OK OK
OK OK
OK OK
OK
OK
OK
OK
OK
OK OK
OK OKOK OKOK OK
OK OKOK OK
OK
OK OK
OK OKOK OKOK OK
OK OKOK OK
OK
OK OK
OK
OK
OK
OK OK
OK OKOK OKOK OK
OK OKOK OK
OK
OKOK
OK OK
OK OKOK OKOK OK
OK OKOK OK
OK
OKOKOK OKOK
OK OK
OK OK
OK
OK
OK
OK
O.RNGI.RNG
O.RNGI.RNG
999999991
5.00
5.00
999899982
4.99
4.99
00010001
4
-4.99
-4.99
000000005
-5.00
-5.00
PASSPASS
LIGH
TR.LO
TR.HI
correct
password
correct
password
incorrect
password
incorrect
password
if pass-
word was
selected
if pass-
word was
selected
if OK
pressed
≥ 2 s
if no
password
was se-
lected
if no
password
was se-
lected
OKOKOK
OK
OK
OKOK
OK
OK
OK
OKOKOK
OK
OK
OKOK
OK
OK
OK
up
down
OK
OK
YES
YES
NO
NO
TRIM
TR.RS
OK
OK
OK
LED-DISPLAY
START
Flussdiagramm / Flow diagram / Diagramme de ux / Diagramma di usso / Diagrama de ujo / 流程图
I
Display help text
Process value
("Start")
NB The display is normally OFF in
process state!
NO.CA
➨
DEVICE NOT CALIBRATED
DP.ER
➨
CHECK DIP SETTINGS
TR.ER
➨
CHECK TRIM PARAMETERS
EE.ER
➨
CHECK CONFIGURATION
RA.ER
➨
Conguration setup PASS
(any)
➨
SET CORRECT PASSWORD
IN
(any)
➨
SELECT INPUT TYPE
read-only CONFIGURED INPUT TYPE
I.RNG
(any)
➨
SELECT INPUT RANGE
read-only CONFIGURED INPUT TYPE
IN.LO
(any)
➨
SET INPUT RANGE LOW
IN.HI
(any)
➨
SET INPUT RANGE HIGH
OUT
(any)
➨
SELECT OUTPUT TYPE
read-only CONFIGURED OUTPUT TYPE
MODE
(ACTI)
➨
SELECT ACTIVE OUTPUT
(PASV)
➨
SELECT PASSIVE OUTPUT
O.RNG
(any)
➨
SELECT OUTPUT RANGE
read-only CONFIGURED OUTPUT RANGE
OU.LO
(any)
➨
SET OUTPUT RANGE LOW
OU.HI
(any)
➨
SET OUTPUT RANGE HIGH
Bandwidth setup BW
(any)
➨
SET BANDWIDTH
Password setup E.PAS
(any)
➨
ENABLE PASSWORD PROTECTION
N.PAS
xxxx
➨
SET NEW PASSWORD
Display light
intensity
LIGH
xx
➨
SET DISPLAY INTENSITY
TRIM functionality TRIM
(any)
➨
ENABLE OUTPUT TRIM
TR.RS
(any)
➨
RESET TRIM SETTINGS
TR.LO
(CURR)
➨
SET TRIM LO VALUE IN [µA]
(VOLT)
➨
SET TRIM LO VALUE IN [mV]
TR.HI
(CURR)
➨
SET TRIM HI VALUE IN [µA]
(VOLT)
➨
SET TRIM HI VALUE IN [mV]
Polarity invertion
info
Scolling help text
–
passive
➨
INVERT INPUT WIRE POLARITY
inverted
➨
INVERT OUTPUT WIRE POLARITY
NOTICE
• The display is switched o until “OK” is pressed or
held for more than 1.5 s to set the display brightness.
• If the “OK” button is pressed for more than 2 s, the
conguration program returns to the previous menu
item.
• The conguration program is terminated if the buttons
are NOT pressed for more than 2 min.
*1) Both buttons must be pressed simultaneously.
*2) The password “1001” is always accepted.
*3) Only visible if password entry is enabled. (“E.PAS” = “YES”)
*4) If “TRIM” = “NO”, storeded values “TR.LO” and “TR.HI” will
be reset to “0”.
*5) Values are entered in “µA” or “mV”, depending on the ac-
tive conguration. They are reset to “0” if the conguration
is changed.
*6) If a DIP switch conguration has been selected, the menus
are displayed as “read only”.
*7) When set to “CURR” combined with “MODE” = “PASV” only
the range 4...20 mA can be selected.
*8) CURR unit VOLT unit condition
0
:
:
:
:
±999
µA
0.0
:
+99.9
mV
Only displayed if
“I.RNG” = “SPEC”.
The displayed val-
ue is automatically
scaled.
±100
:
±999
±1.00
:
±9.99
mA
±1.00
:
±9.99
V
Only displayed if
“O.RNG” = “SPEC”.
The displayed val-
ue is automatically
scaled.
±10.0
:
±99.9
±10.0
:
±99.9
±100
±100
:
±300
*9) The display only shows the upper range value.
*10) When set to “MODE” = “PASV” or with an inverted output
range, a scrolling text display indicates that either the two
input cables or the two output cables need to be swapped
over.
Display
DIP switch
˄ Increment value / select next item
OK Proceed to next menu or return to
previous menu, when holding button
˅ Decrement value / select previous item
*3)
*1)
*2)
*4)
*5)
*5)
*3)
*2)
*8) *8)
*8)*8) *8) *8)
*8)
*8)
*10)
*7)
*6)
*6)
*6)*6)
*6)
*6)
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
up
down
Scrolling
info
text
*9)
*9)
*9)
*9)
(10 Hz)
(10 KHz)
INPUT OUTPUT OUTPUT MODE BANDWIDTH PASSWORD
2508060000/04/08-2020