Approval/Certificate/Document of Conformity

[13] Schedule
[14] TYPE EXAMINATION CERTIFICATE No.
DEMKO 18 ATEX 1861X Rev. 1
00-IC-F0060-1 Issue 15.1 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 2 of 3
[15] Description of Product:
These devices are considered Open-Type Analogue Signal Converter, which can connect with 2- or 3- wire transmitter or current source
signal. The input and output circuits and the voltage supply are completely electrically isolated. The input signal is converted into a DC
current or voltage value. These units do not have a complete electrical enclosure and are to be installed in Industrial Control Equipment in
the final installation.
Nomenclature for type ACT20P Series:
ACT20P
-
2CI
2CO
12
-
P
S
1
2
3
4
5
6
1: Product series:
ACT20P
2: Input signal:
CI: Type with one channel of current input signal
2CI: Type with two channels of current input signal
3: Output signal:
CO: type with one channel of current output signal
2CO: type with two channels of current output signal
VO: type with one channel of voltage output signal
4: Variants Width:
Blank: 12.5mm width, for models except for ACT20P-2CI-2CO series
12: 12.5mm width, only for ACT20P-2CI-2CO series
5. Din rail bus power connector:
Blank: Normal type
P: Type support Din rail bus power connector
6: Input/Output connector type:
S: Type with screw connector
P: Type with push-in connector
The optical radiation output of the product with respect to explosion protection, according to Annex II clause 1.3.1 of the Directive
2014/34/EU is covered in this certificate based on Exception 1) to the scope of EN 60079-28:2015.
Temperature range:
The ambient temperature range is -20 C to +60 C.
Electrical data
Cat. No.
Supply
Input
Output
Current Range
Signal input
Voltage
Current
ACT20P-CI-VO-S
ACT20P-CI-VO-P
ACT20P-CI-VO-P-S
ACT20P-CI-VO-P-P
20-30 V dc, 60 mA
0~20 mA or
4~20 mA
2- or 3-wire transmitter,
current source
0~10 V or
2~10 V
-
ACT20P-CI-CO-S
ACT20P-CI-CO-P
ACT20P-CI-CO-P-S
ACT20P-CI-CO-P-P
20-30 V dc, 60 mA
0~20 mA or
4~20 mA
2- or 3-wire transmitter,
current source
-
0~20 mA or
4~20 mA
ACT20P-CI-2CO-S
ACT20P-CI-2CO-P
ACT20P-CI-2CO-P-S
ACT20P-CI-2CO-P-P
20-30 V dc, 75 mA
0~20 mA or
4~20 mA
2- or 3-wire transmitter,
current source
-
0~20 mA or
4~20 mA
ACT20P-2CI-2CO-12-S
ACT20P-2CI-2CO-12-P
ACT20P-2CI-2CO-12-P-S
ACT20P-2CI-2CO-12-P-P
20-30 V dc, 100 mA
0~20 mA or
4~20 mA
current source
-
0~20 mA or
4~20 mA
Routine tests:
N/A
[16] Descriptive Documents
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate.