Approval/Certificate/Document of Conformity

IECEx Certificate
of Conformity
Certificate No.: IECEx UL 19.0056X
Date of issue: 2019-10-29
Page 3 of 3
Issue No: 0
EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:
SPECIFIC CONDITIONS OF USE: YES as shown below:
Annex:
Annex to IECEx UL 19.0056X Issue 0.pdf
These devices are considered Open-Type Analogue Signal Converter, which can connect with current or voltage source signal. The signal
0/4 -20mA or 0-5/10V is isolated and transferred through output side.
Please see Annex for additional information.
The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP54 in accordance with IEC 60079-0 and
only accessible by use of a tool.
The equipment shall only be used in an area of at least pollution degree 2, as defined in IEC 60664-1.
Transient protection shall be provided that is set at a level not exceeding 140 % of the peak rated voltage value at the supply terminals to
the equipment.