6 Detailbeschreibungen I/O-Module | Analoges Ausgangsmodul UR20-4AO-UI-16-DIAG
314 1432780000/08/12.2015Handbuch u-remote
Diagnosedaten UR20-4AO-UI-16-DIAG
Name Byte Bit Beschreibung Default
Fehlerindikator 0
0 Module error
1 Internal error
2 External error
3 Channel error
4 Reserved 0
5 Power supply fault
6 Reserved 0
7 Parameter error
Modultyp 1
0
Module Type 0x05
1
2
3
4 Channel information available 1
5 ... 7 Reserved 0
Fehlerbyte 2 2 0 ... 7 Reserved 0
Fehlerbyte 3 3
0 ... 2 Reserved 0
3 Internal diagnostic FIFO full
4 Power supply fault
5 Reserved 0
6 Reserved 0
7 Reserved 0
Kanaltyp 4
0 ... 6 Channel type 0x73
7 Reserved 0
Diagnosenbits
pro Kanal
5
Number of diagnostic bit per
channel
8
Anzahl Kanäle 6
Number of similar channels per
module
4
Kanalfehler
7
0 Error at channel 0
1 Error at channel 1
2 Error at channel 2
3 Error at channel 3
4 ... 7 Reserved 0
8 ... 10 0 ... 31 Reserved 0
Fehler Kanal 0 11
0 Parameter Error
1 Overtemperature
2 Overload
3 Error
4 Line break
5 ... 7 Reserved 0
Fehler Kanal 1 12
0 Parameter Error
1 Overtemperature
2 Overload
3 Error
4 Line break
5 ... 7 Reserved 0
Diagnosedaten UR20-4AO-UI-16-DIAG
Name Byte Bit Beschreibung Default
Fehler Kanal 2 13
0 Parameter Error
1 Overtemperature
2 Overload
3 Error
4 Line break
5 ... 7 Reserved 0
Fehler Kanal 3 14
0 Parameter Error
1 Overtemperature
2 Overload
3 Error
4 Line break
5 ... 7 Reserved 0
Fehler Kanal 4
...
Fehler Kanal 31
15 ... 42 0 ... 7 Reserved 0
Zeitstempel 43 ... 46 time stamp [µs] (32bit)
Prozessdaten
1)
Ausgänge UR20-4AO-UI-16-DIAG
Byte Format Beschreibung
QB0
Wort AO0
QB1
QB2
Wort AO1
QB3
QB4
Wort AO2
QB5
QB6
Wort AO3
QB7
1) Internes Prozessdatenmapping bei Datenformat „Standard“. Je nach Feld-
busspezifikation und Datenformateinstellung der kommunizierenden Feldbus-
komponenten können Bytes und/oder Wörter bei der Datenübertragung gedreht
werden.