User manual
6 DetaileddescriptionsofI/Omodules | Digital output module UR20-16DO-P-PLC-INT
193Manual u-remote1432790000/08/12.2015
DigitaloutputmoduleUR20-16DO-P-PLC-INT(OrderNo.1315270000)
The digital output module UR20-16DO-P-PLC-INT can con-
trol up to 16 actuators each with a maximum of 0.5 A. The
actuators are connected via a standard PLC connection (20-
pole). A status LED is assigned to each channel in a separate
block. The module electronics can supply the actors with
power from the 4-pole feed-in plug (connector4) via the PLC
connection. Vice versa the module can be supplied via the
PLC connection.
For the PLC connection, the following applies: a maximum
current of 2A (with a max. of 1A per contact) can be taken
from the +24V connections or fed through the 0V connec-
tions.
The power supply of the peripherals con-
nected has to be calculated for each individual
installation situation. When using a at ribbon
cable, please regard its higher internal resist-
ance!
16 x DO 16 x DO
4
2
1
3
4
4
2
1
3
4
24 V DC
24 V DC
GND
GND
+ +
2019
1
24 V DC
24 V DC
GND
GND
2019
1
1 2
0
1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
0
1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
16DO·P 16DO·P
Connection diagram UR20-16DO-P-PLC-INT
1 Total current < 2A
2 Total current > 2A
6.21 Digital output module UR20-16DO-P-PLC-INT