User manual
6 DetaileddescriptionsofI/Omodules | Digital output module UR20-8DO-P-2W-HD
187Manual u-remote1432790000/08/12.2015
Technical data UR20-8DO-P-2W-HD (Order No. 1509830000)
System data
Data
Process, parameter and diagnostic data depend on the coupler used,
see the table in Section 4.10.
Interface
u-remote system bus
System bus transfer rate
48 Mbps
Outputs
Number
8
Type
P-switching
Type of load
ohmic, inductive, lamp load
Response time
low » high max. 50 µs; high » low max. 100 µs
Max. output current
per channel 0.5A
per module 4A
Breaking energy (inductive)
150mJ per channel
Switching frequency
Ohmic load (min. 47 Ω) 1kHz
Inductive load (DC 13) 0.2Hz without free-wheeling diode
1kHz with suitable free-weheeling diode
Lamp load (12W) 1kHz
Actuator connection
2-wire, 2-wire + FE
Short-circuit-proof
yes
Protective circuit
Constant current with thermal switch-off and automatic restart
Response time of the current limiting circuit
<100µs
Module diagnosis
yes
Individual channel diagnosis
no
Reactionless
yes
Can be used with PF-O-xDI-SIL
yes
Supply
Supply voltage
24V DC +20 %/-15 %
Current consumption from system current path I
SYS
8mA
Current consumption from output current path I
OUT
40mA + load
Connection data
Type of connection
Insulation Displacement Connection (IDC)
Line connection cross-section
Single-wired, Fine-wired 0.14 … 0.35mm
2
General data
Weight (operational status)
88g
For additional general data, see Section 3.4