Safety data sheet

Safety Data Sheet according to Regulation (EC)
No. 1907/2006 (REACH)
Printed 08.01.2016
revision 18.06.2015 (GB) Version 8.3
Electro-Contact-Cleaner Spray
WEICON GmbH & Co. KG Königsberger Straße 255 D-48157 Münster / Federal Republic of Germany Page 5/10
Hygiene measures
At work do not eat, drink and smoke.
Wash hands before breaks and after work.
Advice on protection against fire and explosion
Keep away from sources of ignition - No smoking
Do not spray on a naked flame or any incandescent material.
Protect from heat and sunlight.
Vapours can form an explosive mixture with air.
Take precautionary measures against static discharges.
7.2. Conditions for safe storage, including any incompatibilities
Requirements for storage rooms and vessels
Adhere to administrative regulations relating to storage of compressed gas cylinders / containers.
Advice on storage compatibility
Do not store together with food.
Further information on storage conditions
keep dry and cool. The local authorities’ regulations relating to the storage of compressed gas packagings (aerosol
cans) must be adhered to.
Protect from heat and direct solar radiation.
Keep container in a well-ventilated place
Storage temperature may not exceed 50°C (=122°F).
Recommended storage temperature: room temperature.
7.3. Specific end use(s)
Recommendation(s) for intended use
See section 1.2
! SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Ingredients with occupational exposure limits to be monitored
CAS No Name Code [mg/m3] [ppm] Remark
106-97-8 Butane 8 hours 1450 600
Short-term 1810 750
EH40/2005
64-17-5 ethanol 8 hours 1920 1000 EH40/2005
Indicative occupational exposure limit values (91/322/EEC, 2000/39/EC, 2006/15/EC or 2009/161/EU)
CAS No Name Code [mg/m3] [ppm] Remark
109-66-0 pentane 8 hours 3000 1000
!
Additional advice
The statutory local and national regulations have to be observed.
8.2. Exposure controls
Respiratory protection
If ventilation insufficient, wear respiratory protection.
Short-term: filter apparatus, filter AX, otherwise environment-independent breathing apparatus.
!
Hand protection
In the cases of special applications, it is recommended to check the chemical resistance with the manufacturer of the
gloves.
In the cases of special applications, it is recommended to check the chemical resistance with the manufacturer of the
gloves.
Glove material specification: Nitile rubber