Specifications

Over Current Ev counts the number of times the LNB drew too much current. These events
(Ev) always should be 0. If not, you should check your LNB.
I2C Errors (I squared C – I
2
C) count the errors the processor has. Any errors here indicate an
internal problem in the receiver and it will need to be repaired.
Lost Lock Ev counts the number of time the receiver lost its lock with the carrier. If these
events (Ev) happen, you should make sure your dish is properly aligned. It also happens
during the spring and fall sun transit outages, because the carrier is lost when the satellite
comes directly between your antenna and the sun. If nothing has changed, then this
should be 0.
Data Statistics
DATA STATISTICS
-------------------------------------
Control Address: 239.239.239.128
Control Port: 23456
Control Pkts: 5622
MPEG IRQs: 93079005
Transp Pkts: 1478019952
Transp Pkt Errs: 28
Transp Syn Errs: 0
Data Queue: 0 of 2000132
Data Queue Max: 78396
Data Queue Ovf: 0
Control Address is the address used by the receiver to receive commands from the Command
Interface.
Control Port is the port used by the receiver to accept the commands from the Control
Address.
Control Pkts (control packets) reflect the number of packets sent to the receiver from the
Command Interface.
MPEG IRQs (MPEG Interrupt Requests) count the number of interrupt requests generated to
process data from the transport stream.
Transp Pkts (Transport Packets) counts the number of packets received from the transport
stream.
Transp Pkt Errs (Transport Packet Errors) counts the number of packet errors from the
transport stream. This number should be low; however, during the Sun Transit Outages,
this will climb up significantly. If you see this number increasing, make sure you check
your equipment. Severe weather also could cause it to climb. Most of the errors will be
fixed by the FEC (Forward Error Correction).
Transp Syn Errs (Transport Packet Synchronous Errors) counts the packets that do not have a
valid header. This should be 0 most of the time.
Data Queue gives you the size of the queue and is a fixed number. This is the temporary
storage for data as it comes from the data stream.
Data Queue Max is the amount of valid data in the queue to be processed.
Data Queue Ovf (Overflow) counts the number of times the data queue overflowed the data
queue. This should always be 0.
Rev. 36 – Firmware version 1.61 46
©