Specifications

*Alarm: ON (default)
Relay #6 closes on any of the following conditions:
1. Loss of RF
2. A short to the LNB
To turn the alarm off, use the following procedure.
1. Press [ENTER] to access the menu.
2. Press [ENTER] to edit the menu.
3. Press [DOWN] to get to the RECEIVER UTILITIES
4. Press [ENTER] to edit the utilities
5. Press [DOWN] to get to ALARM
6. Press [ENTER] to set it to OFF
7. Press [BACK] to save the changes
8. Press [BACK] until you are back to the main screen
Eb/No: 11.00 (This is relative your location, dish size, alignment, cable type and distance)
Avg BER: 6 (This is the average Bit Err Rate and should be under 10 normally)
AGC: 8500 (This shows the amount of AGC and should be around 8000)
Puncture: 1/2 (This is the Forward Error Correction rate)
Shorts: 0 (This counts the number of shorts on the LNB and should be 0 normally)
Lost Lock: 0 (This counts the number of times the receiver lost lock on the signal and
normally should be 0)
Badblock: 25 (This counts the number of bad data blocks received and it should be less then
30)
*Align: Off (default) This puts the receiver in dish alignment mode – see DISH
ALIGNMENT section.
1. Press [ENTER] to enable the dish alignment mode – This brings up a screen with:
a. 80 (No lock)
b. Symlock 11.98 – it will stay on that display until any other key is pressed
2. Press any key to return Receiver Utilities submenu
*Clock Interval (Time sync relay) – default: OFF
This selects the minutes and seconds when relay #5 closes to synchronize your clocks. This
can be set to any minutes or seconds you desire.
The time sync used on the Wegener Unity 4000® is
at 54:30. The following procedure sets the time
sync relay on and the relay closure at 54:30. The
receiver comes shipped with this function off.
1. Press [ENTER] to access the menu
2. Press [ENTER] to edit the menu
3. Press [DOWN] to get to the CLOCK INTERVAL
4. Press [ENTER] to edit the settings
5. Press [ENTER] to turn the relay ON
6. Press [DOWN] to get to MINUTES:
7. Press [ENTER] to set it to 54
8. Press [DOWN] to get to SECONDS:
9. Press [ENTER] to set it to 30
10. Press [BACK] to save the changes
11. Press [BACK] until you are back to the main screen
The Time Sync relay closes for one second at the MM:SS setting. With the example listed
above, relay #5 would close every hour at XX:54:30 and open at XX:54:31.
Rev. 36 – Firmware version 1.61 34
©
2008
Off
Minutes
Seconds
Clock Interval