Specifications
Receiver Utilities
The Receiver Utilities Submenu has the
following options (* – means the value can
be changed, but it is NOT on the display).
*PID: 0x400
*Freq: 01.106575000
*Symrate: 07140000
*Alarm: ON (default – assigned to Relay #6)
Eb/No: 10.00
Avg Ber: 5
AGC: 8555
Puncture: 1/2
Shorts: 0
Lost Lock: 0
Bad Block: 20
*Align: Off
Receiver Utilities – Submenu Items
*PID: 0x400 (This is the main Program ID of the
carrier and should not be changed unless instructed to do so by support personnel).
1. Press [ENTER] to select 4 (or the first digit after the 0x…)
2. Press [UP] or [DOWN] to change the digit to the desired value
3. Press [ENTER] to move to the next one
4. Press [BACK] to return to a previous digit to correct it
5. Press [ENTER] to go to each digit. When you press [ENTER] at the last digit, it will
save your new port number and return to the Receiver Utilities submenu
*Freq: 01.106575000 (This is the frequency of the carrier and should not be changed unless
instructed to do so by support personnel).
1. Press [ENTER] to select 0 (or the first digit in the frequency)
2. Press [UP] or [DOWN] to change the digit to the desired value
3. Press [ENTER] to move to the next one
4. Press [BACK] to return to a previous digit to correct it
5. Press [ENTER] to go to each digit. When you press [ENTER] at the last digit, it will
save your new port number and return to the Receiver Utilities submenu
*Symrate: 07140000 (This is the bandwidth of the channel and should not be changed unless
instructed to do so by support personnel).
1. Press [ENTER] to select 0 (or the first digit of the data rate)
2. Press [UP] or [DOWN] to change the digit to the desired value
3. Press [ENTER] to move to the next one
4. Press [BACK] to return to a previous digit to correct it
5. Press [ENTER] to go to each digit. When you press [ENTER] at the last digit, it will
save your new port number and return to the Receiver Utilities submenu
Rev. 36 – Firmware version 1.61 33
©
2008
Symrate
Alarm
Eb/No
Avg BER
AGC
Puncture
Shorts
Lost Lock
Bad Block
Align
Receiver Utilities
PID
Freq