User`s manual
Unity 4650 User’s Manual
800034-01 Rev. A 68 wegener.com
SETPEDEST
xxx
xxx: “E” for enable or “D” for disable.
Enables or disables the “pedestal” setup, the addition of +7.5 IRE to the lumi-
nance level of active NTSC video. A Local Control Command (available from
the terminal regardless of "Local Control Enable/Disable" commands from the
network).
SETPIN
value
value: Decimal representation of PIN key, between 0 and 16777215.
Command sets the PIN scrambling key number.
SETTIMEOUT
source time
time: Time-out value in seconds or HHHH:MM:SS format. Minimum value is
1, and maximum value 35999999 (9999:59:59 hms) for all others.
Command sets Automated Recovery timeout specified by source to the value
specified by time.
SETUID
[id]
id: Unit ID number between 00 and 99 inclusive.
Command for assigning the unit ID number for gaining "talker" access on a
shared serial bus. The factory default setting for id is '00', which also disables
terminal daisy-chain capability. If the parameter is omitted, then this command
returns the current unit ID setting. Command is only applicable to products that
feature serial "daisy-chain".
source: 1 - Not used. (In legacy IRDs, this was Fade timeout.)
2 - Services Recovery Timeout. (In legacy IRDs, this
was Installation timeout.)
3 - Network Recovery Timeout. (In legacy IRDs, this
was No COMPEL
timeout.
4 - Recovery Iteration Time. (In legacy IRDs, this was
Header Seek timeout.)
5 - Local Control Re-enable Timeout. (In legacy IRDs
this was Local (Control) Recovery timeout.)