User`s manual

Unity 4650 User’s Manual
800034-01 Rev. A 52 wegener.com
DTMFTST
[level] [tone]
level: Integer between 0 and 100 inclusive.
tone: Tone code (0-15 signifying digits 1-9,0,*,#,A-C).
Volatile test command for DTMF output, if supplied. Tones will be output at
the percentage of full-scale voltage indicated by level. If tone is supplied, then
that tone is output continuously. If tone is omitted, then the IRD cycles end-
lessly through all tones, 1 second per tone. Disable with TESTOFF command.
A Local Control Command (available from the terminal regardless of "Local
Control Enable/Disable" commands from the network).
DTMFVOL
percent
percent:Integer between 0 and 100 inclusive.
Command to set DTMF output tone levels. Immediately after entry of the com-
mand, the IRD will play out all 16 tones (at a rate where they are individually
identifiable) at the commanded level. If percent is ‘0’, output is essentially
OFF. If percent is ‘100’, level is maximum spec level. Entering command
without parameters still plays out the tone sequence and then reports current
level setting. A Local Control Command (available from the terminal regard-
less of "Local Control Enable/Disable" commands from the network).
EMAIL
x
x: Either “E” for Enabled, or “D” for Disabled.
Command to enable COMPEL
printed email. A Local Control Command
(available from the terminal regardless of "Local Control Enable/Disable"
commands from the network).
ERRORS
type threshold
type:Either “E” for Errord Seconds or “C” for Continuity-count errors.
threshold:Integer between 1 and 255.
Command to set either Error’d-seconds-rate or Continuity-count Alarm thresh-
old. Unit will show an alarm if, over any previous 60 second interval, the num-
ber of type events which are detected exceeds threshold. A Local Control
Command (available from the terminal regardless of "Local Control Enable/
Disable" commands from the network).