Specifications

Supported Devices
Sumavision Technologies, Inc.
70
--- Input IP alarms ---
All the following are elements related to signal input with type IP. All those elements are displayed in
a subfolder named ‘Input IP’.
LockStatus StatusText/Signal gbeInLockStatus IP Input Status. "unlock" (Critical error) or "lock"
(nominal case).
System Bitrate Text/Signal
gbeInSystemBitrate GBESystem Bitrate
Valid Bitrate Text/Signal
gbeInValidBitrate GBEValid Bitrate
Packet Length Text/Signal
gbeInPacketLength GBEPacket Length. "packet188" or "packet204"
Input IP Text/Signal
gbeInIP Receive Ip
Input Port Text/Signal
gbeInPort Receive Port.(0~65535)
Reference Bitrate
Enable
StatusText/Signal
gbeInRefBitrateEnable Reference bitrate enable. "on" or "off".
Reference Bitrate Text/Signal
gbeInRefBitrate Reference bitrate value.(0~200000000)
Alarm Enable StatusText/Signal
gbeInAlarmEnable Alarm OnOff of GBE input. "on" or "off".
Protocol Text/Signal
gbeInProtocol Protocol of GBE receive. "udp" or "rtp".
--- Output ASI alarms: Out 1 ---
All the following are elements related to signal output with type ASI.
There are two output ports. The following is the set of alarms for Port 1.
Subfolder: Output ASI/Out 1
System Bitrate Text/Signal asiOut1SystemBitrate ASI port1 out System Bitrate
Valid Bitrate Text/Signal
asiOut1ValidBitrate ASI port1 Valid Bitrate
Stream source Text/Signal
asiOut1Source Stream source of ASI por1 out. Can be "asi", "dvb-s-
s2", "ds3", "gbe", "descrambled"
alarm OnOff Statustext/Signal
asiOut1AlarmEnable ASI port1 out alarm OnOff. "on" or "off".
--- Output ASI alarms: Out 2 ---
All the following are elements related to signal output with type ASI.
There are two output ports. The following is the set of alarms for Port 2.
Subfolder: Output ASI/Out 2
System Bitrate Text/Signal asiOut2SystemBitrate ASI port2 out System Bitrate
Valid Bitrate Text/Signal
asiOut2ValidBitrate ASI port2 Valid Bitrate
Stream source Text/Signal
asiOut2Source Stream source of ASI por2 out. Can be "asi", "dvb-s-
s2", "ds3", "gbe", "descrambled"
alarm OnOff Statustext/Signal
asiOut2AlarmEnable ASI port2 out alarm OnOff. "on" or "off".
--- Output IP: Global Ethernet alarms ---
Ethernet Link Status status/Signal gbeLinkStatus Link Status. Set to NORMAL if variable equals "Link
up".
Health monitoring alarms (
Continued)
Alarm name Type MIB point Further details