Specifications
Supported Devices
MIBs Used
46
Alarm name Type MIB point Further details
--- Converter alarms
1
---
cvalr MIB point gives Local oscillator alarm and Power supply alarm.
mute and pol are text alarms that only provide information
acvstat MIB point gives informations for Redundancy Chain status alarms and serial link status
converter alarm.
Local Oscillator Alarm Status/health cvalr Local Oscillator Alarm
2
This alarm may occur if the specified converter is
not installed. It also may happen if the converter
cannot be selected with an SNMP set.
Power Supply Alarm Status/health
cvalr Power Supply Alarm
2
This alarm may occur if the specified converter is
not installed. It also may occur if the converter
cannot be selected with an SNMP set.
Mute Text/health
mute Mute converter output for the converter selected
by the most recent
cvsel setting.
3
Polarization Text/health
pol Polarization setting for the converter selected by
the most recent
cvsel setting.
3
Allowable settings:
•0 - N/A
•1 - None
•2 - Horizontal
•3 - Vertical
Serial Link Status
converter
StatusText/health
acvstat Converter serial link status indicator
• 0 = No Fault - NSU-Converter Serial Link
enabled and communicating
• 1 = Fault - NSU-Converter Serial Link enabled
and not communicating
• 2 = No Fault - NSU-Converter Serial Link
disabled
• - = No Fault - Chain position inactive
Redundancy chain
status
StatusText/health
acvstat Redundancy chain status indicator
• 0 = No Fault - chain position active
• 1 = Fault -chain position active (Fault reported
normally)
• 2 = Fault - chain position active both contacts
open
• 3 = Fault - chain position active both contacts
closed
• - = chain position inactive disconnected from
redundancy chain
• + = chain position inactive connected to
redundancy chain