Specifications

Supported Devices
Plug-in Notes
44
Certain parameters may be passed to the plug-in, as follows:
Plug-in Notes
This plug-in is based on generic.js.
All MIB points are static.
reference Text/health moreStatus internal/external reference
polarization Text/health
moreStatus polarization (none, horizontal, vertical)
setup title Text/health
moreStatus Setup Title
slope Text/health
moreStatus Slope in dB
impedance Text/health
moreStatus 50 ohm or 75 ohm
Parameter Description
AlarmPath Used to set the Alarm prefix.
Default:
PBI.
Could be replaced by
IRD so as to have legacy plug-ins tree look-like.
pollInterval Poller interval in seconds. Overwrite the default interval of 20 seconds.
retries If an SNMP request times out, this defines the number of retries to be performed.
Default:
1.
timeout Delay in seconds before declaring a timeout in the current SNMP request.
uniqueID An extra identifier to be assigned to the plug-in to differentiate its alarms from the other
plug-in of the same type. The
uniqueID should be part of the URI.
readCommunity SNMP read community string. Use for SNMP polling.
Default:
public
pos15vThresh
Threshold for +15V voltage supervisor.
Default:
5V
The alarm +15V Supply rail becomes critical when the measured voltage is under the
threshold.
pos5vThresh Threshold for +5V voltage supervisor.
Default:
2V
The alarms +5V Supply rail A and +5V Supply rail B become critical when the measured
voltage is under the threshold.
neg15vThresh Threshold for -15V voltage supervisor.
Default:
5V
The alarm -15V Supply rail becomes critical when the measured voltage is above the
threshold.
(
Continued)
Alarm name Type MIB point Further details