Specifications
iControl
Supported Device Reference Guide
43
--- Info alarms ---
Theses alarms are created by the plug-in itself
Transfer Switch Mode Status/health xferSwflt Transfer Switch Indicator switch fault status
Summary Alarm Status/health Summary Alarm Summary (overall) Alarm status
+15V Supply rail StatusText/health
pos15rail +15.3V Supply rail. Alarm is set to CRITICAL when
the measured voltage is under the parameter
pos15vThresh.
+5V Supply rail A StatusText/health
pos5Arail +5V Supply rail A. Alarm is set to CRITICAL when
the measured voltage is under the parameter
pos5vThresh.
+5V Supply rail B StatusText/health
pos5Brail +5V Supply rail B. Alarm is set to CRITICAL when
the measured voltage is under the parameter
pos5vThresh.
-15V Supply rail StatusText/health
neg15rail -15V Supply rail. Alarm is set to CRITICAL when the
measured voltage is above the parameter
neg15vThresh.
Temperature Text/health
temperature Temperature in degrees C
Local Oscillator Lock
Alarm
Status/health
moreStatus Local Oscillator Lock Alarm
Power supply Alarm Status/health
moreStatus Power Supply Alarm
Local Oscillator Level
Alarm
Status/health
moreStatus Local Oscillator Level Alarm (Optional)
Amplifier Current
Alarm
Status/health
moreStatus Amplifier Current Alarm (Optional)
External Alarm Status/health
moreStatus External Alarm
Temperature Alarm Status/health
moreStatus Temperature Alarm (Optional)
Module
communications
Alarm
Status/health
moreStatus Module communications Alarm (Optional)
--- Status path alarms ---
frequency Text/health moreStatus Frequency in Hz
attenuation Text/health
moreStatus attenuation
attenuation 2 Text/health
moreStatus optional second attenuation
attenuation 3 Text/health
moreStatus optional third attenuation
control Text/health
moreStatus local or remote
intermediate freq Text/health
moreStatus intermediate frequency
mute Text/health
moreStatus muted or not
(
Continued)
Alarm name Type MIB point Further details