Specifications

iControl
Supported Device Reference Guide
23
Certain parameters may be passed to the plug-in, as follows:
--- RX alarms ---
RX data are on two cannons Laser A and Laser B, the information displayed is done for both.
table of indexes : laserA ( 1 ) , laserB ( 2 )
rxLaserPowr Text FC3405-MIB polling and
trap
tells about SFP RX received power status
rxReclock Text polling and
trap
displays the reclocker status
--- Notify alarms ---
This status are displayed for each index of this table.
Table of indexes : txCarrier1 ( 1 ) , txCarrier2 ( 2 ) , rxLoss1 ( 3 ) , rxLoss2 ( 4 ) , rxOptPwrHigh1 ( 5 ) ,
rxOptPwrHigh2 ( 6 ) , rxOptPwrLow1 ( 7 ) , rxOptPwrLow2 ( 8 ) , noInputDetected1 ( 9 ) ,
noInputDetected2 ( 10 ) , reclockerLoss1 ( 11 ) , reclockerLoss2 ( 12 ) , txLaserFault1 ( 13 ) ,
txLaserFault2 ( 14 ) , sfpCommunicationLoss ( 15 )
mgmtFaultPresent Status polling and
trap
Check the status of fault(s
SendMgntTrap Status
FC3405-MIB polling and
trap
Used to Turn Traps On and Off
trapValid Status polling and
trap
Indicate if a particular trap is applicable to
current SFP instance
--- Coax alarms ---
All the following are elements related to signal output with type ASI.
Coax signals are on two cannons Channel A and Channel B, the information displayed is done for
both.
Tables of index : ChannelA ( 1 ) , ChannelB ( 2 )
SignalRate Text polling and
trap
Indicates the signal rate detected by the
reclocker
SignalPresence Status
FC3405-MIB polling and
trap
Indicates the signal presence on the indexed
channel
SignalLock Status polling and
trap
Indicates the status of the signal lock of the
reclocker
CableEqualization Text polling and
trap
Indicates the percentage of cable
equalization of the indexed channel
Health monitoring alarms (
Continued)
Alarm name Type MIB point Polling or
trap?
Further details