Specifications
Supported Devices
Evertz
22
• Notify alarms
Health monitoring alarms
Alarm name Type MIB point Polling or
trap?
Further details
--- Health monitoring alarms ---
Device
Communication
status/health sysUpTime
(RFC1213)
Polling Device communication alarm set by
receiving a successful/failed event in the
poller
Device Restart status/health
sysUpTime
(RFC1213)
Polling Raise a minor condition based on the value of
sysUpTime read is smaller by at least
60 seconds compared to last reading. The
value increase by 100 every second.
System uptime status/health
sysUpTime
(RFC1213)
Polling System up time alarm, this is a default health
monitoring alarm when you use the
generic.js to create a new custom driver
--- Monitor alarms ---
The device has sixteen SFP ports. The information on alarms will be displayed for each valid SFP on
the device.
Version Text Polling Version number for the SFP module
Upgrade Support Status Polling Indicates whether the SFP firmware can be
upgraded using the second stage bootloader
Serial number Text Polling Serial number for SFP module
Id Text Polling Describe the specific type of SFP
Class Text
FC3405-MIB Polling Describe the base class of SFPs
--- TX alarms ---
TX data are on two cannons Laser A and Laser B, the information displayed is done for both tables
of index : laserA ( 1 ) , laserB ( 2 )
txBiasCurrent Text FC3405-MIB Polling and
trap
Displays bias current on laser in units of
0.01 mA
txLaserEn Text Polling and
trap
Tells about SFPTX laser status
txLaserStatus Text Polling and
trap
Tells about wavelength supported by
SFPTX's lasers
txReclock Text polling and
trap
displays the reclocker status
txWavelength Text polling and
trap
tells about SFP TX laser status