Instruction manual

Page 53
Page 53 of 74 UTY4422-001
Where “xxxxx” is baud-rate, either 9600 or 19200 baud. “y” is parity, either “O” (for Odd), “E”
(for Even), or “N” (for None).
M O D E M S E T T I N G S
B A U D x x x x x P A R I T Y N
Where “xxxxx” is the baud-rate, either 9600 or 19200 baud. Parity is always “None.”
A U X D A T A P I D : X X X X
B A U D x x x x x P A R I T Y p
Where Baud is 1200, 2400, 4800, 9600, 19200, or 38400. Parity is None, Even, or Odd.
R E T U R N :
P r e s s < S E L E C T >
1.3.7 Test Mode
T E S T M O D E : X X X X X X X X
Where ‘xxxxxxxx’ is either ‘enabled’ or ‘disabled.’
Enabled: Modulated Ramp Test Signal.
1.3.8 LNB DC Power
L N B D C P O W E R : x x x
Where ‘xxx’ is either ‘on’ or ‘off.’
On: 24v. Off: 0v.
R E T U R N
P r e s s < S E L E C T >
Returns to 2nd level screens under “HARDWARE SETUP.”
B1.3.9 LNB LO’s
If the optional RF Switch is NOT installed, the following screen is shown:
L N B L O : 0 0 0 0 0 . 0 0
If the RF Switch is installed, two screens are shown, as follows.
L N B L O : 0 0 0 0 0 . 0 0 #