Instruction manual

Page 48
UTY4422-001 Page 48 of 74
A1.1.12 SETLNB
LO_freq
LO_freq: This value represents the LNB LO frequency in MHz. It can have up to two decimal
places and its valid range is from 0 to 14422.00.
Sets lnb_lo_freq to LO_freq.
A1.1.13 SETTIMEOUT
source time
source: 1 - Fade
2 - Installation
3 - Carrier Search
4 - No COMPEL
5 - Header Seek
6 - Header Search
time: Time-out value in HH:MM:SS format. Valid range is 00:00:00 to 9999:59:59.
Timeout.source is set to time..
A1.1.14 SNR
alarm_level margin_offset
alarm_level: Units of dB with range from 5.0 - 14.9 and can have one decimal place.
margin_offset: Units of dB with range from 1.0 - 10.0 and can have one decimal place.
Sets alarm_level and margin_offset accordingly.
A1.1.15 TEMP
settings time
settings: See Perms/Temps/Searching & Settings, Section 3.8.1.
time: Length of insert in HH:MM:SS format. Valid range is 00:00:00 to 18:00:00.
Will handle data rate rounding as explained for PERM. Unit sets its temp_settings to settings.
See Perms/Temps/Searching & Settings, Section 3.8.1, for more information.
A1.1.16 TEMPCH
location time
location: Value from 1 - 48 indicating location in settings_table.
time: Same as for TEMP.
Unit sets it temp_settings to those retrieved from the settings_table according to location.
A1.1.17 UNMUTE [source][source]
source: Same as the MUTE command.
Identical to MUTE except specified services are unmuted.