HYDRO-CORE MANIFOLD OPTIONS
Identify the System Run Size & Desired Con guration to
Select Your Speci c Manifold • Recommended Size in Bold
INSTALLATION KIT OPTIONS
Choose One of the
Installation Options Below
Manufacturer Model Number
Boiler
Connection
Connection to
Hydro-Core
RECOMMENDED
TYPE
1" Run 1 1/4" Run 1 1/2" Run 2" Run
HYDRO-CORE FLEX
COMPLETE NEAR
BOILER PIPING KIT
NEAR BOILER
COMPONENT KIT
UNION
CONNECTION ONLY
1
SWT FIP SWT FIP SWT SWT 1 1/4" Run IPS 1 1/4" Run SWT
Slant Fin
Jaguar J-390C 1 1/4 MIP 1 1/4 Flange Right - 48755-0 58755-0 48765-0 58765-0 58775-0 - - - FS-245 -
Lynx
LX-90
LX-120
LX-120CB
LX-150
LX-150CB
1 MIP 1 Flange Left - 48854-0 58854-0 48864-0 58864-0 - - - - FT-144
-
-
-
-
-
VSL
VSL-160B 3/4 SWT 1 Flange Right 58744-0 48754-0 58754-0 48764-0 58764-0 58774-0 - - - WH-1R44 -
VSL-160C 3/4 SWT 1 Hydro-Core Flex - Included w/Kit - - - 4FK3-WIS 5FK3-WIS - - -
Triangle Tube
Challenger Solo
CC85s
CC105s
CC125s
CC150s
1 MIP 1 Flange Right 58744-0 48754-0 58754-0 48764-0 58764-0 58774-0 - - - WH-144 -
Keystone
KS399 1 1/4 MIP 1 1/4 Flange Right - 48755-0 58755-0 48765-0 58765-0 58775-0 - - - FT-245 -
KS500
KS600
1 1/2 MIP 1 1/2 Flange Right - - - 48766-0 58766-0 58776-0 -- - - HCE6-56
Prestige Excellence
PTE 110
PTE 110 LP
1 MIP 1 Hydro-Core Flex - Included w/Kit - - - 4FK4-TTS 5FK4-TTS - - -
Prestige Solo
60 1 MIP 1 Flange Right 58744-0 48754-0 58754-0 48764-0 58764-0 58774-0 - WH-144 -
110 1 MIP 1 Hydro-Core Flex - Included w/Kit - - - 4FK4-TTS 5FK4-TTS - - -
175
250
1 1/4 MIP 1 1/4 Flange Left - 48855-0 58855-0 48865-0 58865-0 -- - - WH-245 -
Viessmann
Vitodens 100-W
WB1B 26
WB1B 35
3/4 FIP 1 Flange Right 58744-0 48754-0 58754-0 48764-0 58764-0 58774-0 - - - WH-1R44 -
Vitodens 200-W
WB2B 19
WB2B 26
WB2B 35
3/4 FIP 1 Flange Right 58744-0 48754-0 58754-0 48764-0 58764-0 58774-0 - - - WH-1R44 -
WB2B 45
WB2B 60
WB2B 80
WB2B 105
1 1/4 FIP 1 1/4 Flange Right - 48755-0 58755-0 48765-0 58765-0 58775-0 - - - WH-245 -
Weil-McLain
Ultra
UG-080
UG-105
1 MIP 1 Flange Right 58744-0 48754-0 58754-0 48764-0 58764-0 58774-0 - - - FT-144 -
UG-155
UG-230
1 MIP 1 1/4
5
Flange Right - 48755-0 58755-0 48765-0 58765-0 58775-0 - - - FT-2R45 -
UG-299 1 1/4 MIP 1 1/2
5
Flange Right---48766-0 58766-0 58776-0 -- - - HCE6-56
UG-399 1 1/2 MIP 1 1/2 Flange Right - - - 48766-0 58766-0 58776-0 -- - - HCE6-56
GV90+
GV90+3
GV90+4
1 MIP 1 Double Ball Drain - 48354-0 58354-0 --- - - - -
(IPS) HCE4-44
(SWT) HCE4-54
6
Williamson-
Thermo o
GWA
GWA-052
GWA-070
GWA-105
GWA-140
GWA-175
GWA-210
GWA-245
1 1/4 FIP 1 1/4 Flange Right - 48755-0 58755-0 48765-0 58765-0 58775-0 - - - FS-185 -
GWC
GWC-070
GWC-105
1 FIP 1 Double Ball Drain - 48354-0 58354-0 --- - - - -
(IPS) HCE4-44
(SWT) HCE4-54
6
1 Union connections are available with ports for a pressure gauge or other devices if desired. See brochure for details
5 Manufacturer recommends Minimum Boiler Loop Piping size as indicated.