User`s guide

WebEye E10/E104WebEye E10/E104
User’s Guide
10
Green LED: This LED indicates the status of networking. After power is supplied, it is on for the
first 1-2 seconds, and then it blinks once at every one second as long as the network is connected.
5) Descriptions on DIP Switches
OUT / IN
To configure the function of the first coaxial cable port at the rear of WebEye.
If you set the switch at position OUT, the first port can be used to transmit video signal from
WebEyes inner CCD module to outer displayer such as TV or computer monitor. Setting the first
DIP switch at OUT and the second DIP switch at OFF, you can connect an outer displayer
directly to the first port with coaxial cable. In this case, you may monitor 4 channels (Ch.0, Ch.2,
Ch3, and Ch.4) in WebEyes Homepage through network and also can monitor a channel (Ch.0) on
outer displayer with motion pictures sent from WebEyes inner CCD module. It means that WebEye
could not receive video signal from an external camera, connected to the first coaxial cable port,
though.
If you set the switch at position IN, the first port can be used to receive video signal from external
CCD camera. Setting the first DIP switch at IN and the second DIP switch at ON, you can
Phenomenon of Malfunction
1. Network Malfunction
Green LED blinks once at every 4 seconds
Check if Ethernet cable is connected properly or the Network works.
2. Software Malfunction
Green and yellow LEDs are on, and they blink 6 times rapidly at every 10 seconds.
This problem is to be solved with A/S program.
Contact the dealer from who you bought
WebEye.
After being on for a second, Green and yellow LEDs blink 6 times rapidly. Then green
LED is on and yellow LED is off.
This problem is to be solved by re-installing firmware. Visit WebGate
s Internet homepage