User`s guide
- 47 –
WebEye SPD User’s Guide
(Appendix 5)
WebEye SPD Physical Installation Guide
1. Contents
2. WebEye SPD physical installation procedure .
(1) Before installation, confirm strength
of the location where the “Ceiling
Suspension Bracket” is installed.
(2) Make a hall of 124mm±1mm for
bracket installation
(3) Fix the Bracket to anchor with the
included “Safety Wire”(A). If anchor
point is located near the camera
installation point, you can use it.
Connect the safety wire(A) to bracket
hall(B) with the included bolt and nut.
* Caution
The anchor bolt should be fastened
strongly enough to endure no less
that 10Kgf.
(4) Connect LAN cable to Ethernet
connector (C). When you want to see
the video image through the CCTV
monitor, connect a coaxial cable to
Video Out connector (E)
(5) put the bracket in the installation hall
and fix it with included M4 tapping
screw(F). Before installation of the
bracket, camera data cable (G) had to
be connected to camera body and
pulled toward ceiling.
Item Q’Y Remarks
Ceiling Suspension Bracket 1 Connector B’ D attached
AC Adapter mounting Plate 1
AC Adapter fixing screw M3 6
Camera fixing screw M3 1
Tapping screw M4 3
Safety wire 1
Safety wire fixing bolt & nut
2
Ceiling screw anchor 3 Use this item when necessary