WebEye SPD Manual Ver 1.4 WebEye SPD User’s Guide * This manual is for WebEye SPD 160 Firmware version 1.2.0. If you have later version of firmware, please download the last updated user ’s guide from WebGate’s homepage (www.webgateinc.
FCC Compliance Statement Caution : Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection agains t harmful interference when the equipment is operated in a commercial environmental.
Important Notice 1. WebEye SPD is for indoor use. Therefore note that the CCD (charged coupled device) inside the product can be damaged permanently if the camera lens is exposed to direct sunlight. When you place WebEye SPD under the glaring light, we recommend using an iris lens. If your application demands prolonged exposure to sunlight, you should consider to equip with a sun visor. 2. WebEye SPD is not weatherproof.
CONTENTS I. Introduction ................................ ................................ ................................ ... 6 II. Product Descriptions ................................ ................................ ........................ 8 1. Contents .................................................................................................................................8 2. WebEye SPD Over View and Descriptions.................................................................................
11) Alarm Configuration .........................................................................................................34 12) User Custom Configuration ...............................................................................................34 13) Goto Viewer Page ............................................................................................................ 35 Appendix Detailed Specifications of WebEye SPD-160 ................................ ..........................
I. Introduction • What is WebEye ? WebEye is an Internet-based digital network camera, which adapts high resolution, using image compression mechanism and via network. It connects directly to Ethernet network and provides live motion color pictures over the Internet. WebEye is a microprocessor-based device that contains a digital color camera, web server functionality, optimized hardware for image compression, and physical Ethernet connection. Therefore it does not require any extra S/W or H/W.
User’s Programmable Space – WebEye contains user-programmable and user-configurable spaces that are about 6MB out of 8MB total Flash Memory. It means you have own web server which allows you to create your own homepage or free zone in your WebEye. Embedded Linux Operating System – WebEye adopts cutting-edge technologies of digital image processing & networking.
II. Product Descriptions 1. Contents * Unpack and check all the items as below. Item Description Remarks WebEye SPD Web Camera Server AC Adapter & Power cable AC 24V 60Hz, AC 230V 50Hz Optional Lens Optical 16X : 3.9mm ~ 62.4mm Digital 8X, Auto-iris & Focus Already assembled Manual WebEye SPD User's Guide CD Crossover Cable 1 m crossover cable Red colored Bracket Ceiling Attachment Device Setup Disk Setup Software 2.
3. Descriptions on Rear Port (RS-232 and Digital Input) To connect external devices such as infrared sensors. They are 2pairs of isolated input ports.
III. WebEye Installation Summary, Connecting & Placing 1. Installation Summary • • • • • • Connect Ethernet and Power to WebEye SPD on local network for configuration. Install a setup program for Web Eye SPD in to a PC on local network. Assign an IP address to WebEye SPD and configure administrator’s condition. Configure user ’s condition. Place WebEye for your purpose, and re-connect power and Ethernet. Set the Preset. 2. Connecting • • • Connect Ethernet line to the Ethernet port.
IV. Assigning IP Address and Configuration Administrator’s Condition * Important * To access WebEye, you firstly have to assign an appropriate IP address. When you assign an IP address to WebEye, make sure to use unoccupied IP address, and not to use the default or example IP address. Terminology IP Address IP address is an identification code for computers and devices on a TCP/IP network. Networks using TCP/IP protocol route messages based on the IP address of the destination.
1. Connecting WebEye to a PC 1) Connecting WebEye SPD on Internet or LAN. • You may use Ethernet cable (white colored one) to connect WebEye SPD on Internet or LAN. With this connection remote user may not access WebEye SPD before local user configure its network setting. Dedicated line, xDSL line, cable modem line, ISDN line, and PSTN (telephone) line are available. Internet Router HUB Remote User Ethernet Cable Local User Connect WebEye to a PC through a HUB. 2) Connecting WebEye to a PC.
IP Address Assigning Methods • With se tup program - Assemble and place WebEye - Assign IP address to WebEye using setup program on local network. - Access WebEye through Web browser with the IP address and configure user ’s condition and administrator ’s condition.
2) Assigning IP Address to WebEye After keying in the administrator’s password, click ‘Change IP Addr’ button to change your WebEye’s IP address. Type in a new IP address that you are going to assign to your WebEye. Then confirm it with the ‘OK’ button. 3) Configuring Administrator’s Conditions After assigning a new IP address to user’s WebEye (select a WebEye), you may configure the administrator’s condition of the WebEye.
Request timed out : Request timed out Reply from 200.243.232.178: bytes=32 time=2ms TTL=255 Reply from 200.243.232.178: bytes=32 time=2ms TTL=255 Ping statistics for 200.243.232.178: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milliseconds: Minimum = 1ms, Maximum = 2ms, Average = 1ms If you don’t receive the reply by the 'ping' command, try pressing 'F3' and 'Enter' keys again. Normally ‘Request timed out’ messages appear 7 times before you receive proper reply.
V. Accessing WebEye Hompage & Monitoring Real-time Image After assigning WebEye an IP address, you can configure the WebEye within its own web pages through any standard Web browser on local or remote network . 1. Starting Web browser Start your web browser by entering your WebEye IP address. Then you can see a build-in homepage of WebEye. • Example http://200.243.232.178/ WebEye simultaneously supports up to 100 users.
The installation will not take more than 1 minute. Please, don’t click any button until the installation is completed. 4) FAQ A lot of questions and answers are provided here for troubleshooting. If user has another question that is not answered here, please contact WebGate through its homepage. 3. Viewing WebEye SPD There are 3 viewers of real-time monitoring in WebEye homepage. “Default Viewer ”, “720×468 Viewer” and “Server Push Viewer”. An administrator may set a viewer as a first user interface.
If you want to set a new focusing area, you choose ‘New QBOX’ button. First you place and click your mouse where you want to start and then click again where to stop. You can also use existing area to focus again by clicking ‘Enable QBOX’. ‘Disable QBOX’ is to finish. The image activated Focusing Area function is as below. User may set the quality of out of focused area with ‘Ambient Level’. If you select ‘Level 1’, the quality is similar to focused area.
• Single Shot Mode : If you choose the mode and click the start button, only one frame of image is transferred. Therefore, no other images may be viewed. To go back to the real-time images, just click the button again Resolution: User may select a level of resolution among 5 levels (720x486, 720x243, 360x243, 180x121, 90x60). High-resolution image is big, and it is transmitted at slow speed. Frame Rate: You can choose the transmission speed. If you choose ‘Fastest’, you can get images at fastest speed.
2) 720x486 Viewer By selecting this viewer, a user monitor images of 720 by 486 resolutions. This viewer has the identically same functions of default viewer but the image panel is bigger by 4 times than that of default viewer. 3) Server Push Viewer If WebEye SPD is installed on a network where firewall is, you may access SPD through server -push viewer to monitor real-time images.
further image. To resume transmitting real-time images, click the button again. (2) PTZ mechanism control ‘Preset’ is not supported. Pan and Tilt If you click the buttons, you can move the direction of WebEye to where you want to see. Zoom You may zoom in and zoom out. Focus You may control manually to optimize the image’s focus. Acceleration Rate You may choose moving speed of Pan/Tilt/Zoom mechanism among three steps of fast, normal and slow.
VI. Configuring Administrator’s Condition at Homepage This page is for WebEye Administrator. Administrator can login and control operating status remotely. User can access this page by keying in IP address as well as clicking ‘Start Configuration’ button at Setup program. 1. Administrator Login 1) Accessing through Setup Program First you click on MAC address of WebEye to select a certain one. Then you ke y in its administrator’s password and click ‘Start Configuration’ button in turns.
Date & Time’ panel, the same date and time as is set in administrator’s PC appears. And user may set one’s system(PC)’s date and time into WebEye by clicking ‘Time Synchronization’ button. In ‘Manual Date & Time’ panel, administrator may set date and time. And administrator can synchronize manually set date and time with ‘WebEye Current Date & Time’ by clicking ‘Time Synchronization’ button. Administrator’s E-mail Address: In this panel, administrator records one’s e-mail address.
Select Network Interface: If WebEye is connected on xDSL line that needs PPPoE process, administrator should select ‘xDSL (PPPoE)’. However the xDSL line doesn’t need PPPoE process, administrator should select ‘Ethernet’ though WebEye is connected on xDSL line. Ethernet Interface: Administrator may configure IP address, subnet mask, broadcast address, gateway address, and DNS addresses of WebEye.
Auto IP Registration Function: Administrator may register one’s WebEye by enablin g ‘Auto IP Registration Function’. Registration process is that WebEye detects IP addresses from DHCP server and informs the detected IP addresses to dynamic IP registration server. And the server updates already registered information with new one.
‘Security Configuration’ is a double-checking function to control accessibility, utilizing ‘User Account Configuration’ at the same time. 6) Video Configuration This page is to configure every channel with various conditions. (1) Video Channel State Control Administrator decides whether to utilize video signal from selected channel in WebEye or not. (2) Camera Color Type It is to define whether camera type is color or B/W.
• QBOX Parameters : Administrator sets QBOX area with a mouse to ‘click and drag’. Selected area shows in ‘Left Top Placement’ and ‘Right Bottom Placement’ panels in figures. With ‘Ambient Level’ menu, Administrator may set quality level of unfocused area in the image (out of the focused range). There are 5 levels. Administrator may set level 5(Darker) to make unfocused area dark and get the transmission speed up. • Image Quality Level: Administrator chooses image quality level from 0 to 9.
you have to use relay mail server function. Content-Transfer-Type : It is to define e-mail format. E-mail servers support ‘Base64’ format in common, but some servers not. In the case, you may select the format as ‘Quoted Printable’. (4) E-Mail Event Configuration Event source : Administrator should define with which event E-mail is to be delivered among MD (motion detection), sensor 1, sensor 2. If administrator clicks on sensor1, e-mail is sent when the sensor1 detects events.
8) Pan/Tilt/Zoom Configuration WebEye SPD has various special functions such as 64 point Preset, patrol between two different monitoring areas, or group mode swing between more than two different areas. Using these functions, users can obtain an effect of multi-monitoring system with only 1 WebEye SPD through the Internet. To use WebEye SPD efficiently, us ers should have a good command of these functions. Pan/Tilt/Zoom control menu is mainly composed of “New Preset”, “New Group ” and “Mode ”.
NOTE!! : Java Applet viewer at PTZ Configuration may be so slow in NS 4.7 or others. • Netscape Browser If you install Netscape Browser, you may use Java applet. Unless you can view applet, you should other method. (1) Select preference menu in Netscape main-menu. (2) Select Advanced tab at List control of Preferences dialog, and you can see the information of related java. (3) Select Enable Java, and click ‘OK’ button. (4) Close NS and restart to see the applet.
Pan/Tilt/Zoom Control Panel Add/Change the swing , group mode patrol or camera setting Activating this button enables the built-in auto focus function Tele Far Near Wide Add/Change the single monitoring point as preset Select Assigned Point or Group Pan/Tilt Control Panel (Keep pressing mouse left button anywhere on the panel Add/Change the group of the monitoring areas New Pre set : Users can reserve up to 64 monitoring points where the cam goes by one click.
New Group: This function is designed for sequential group monitoring of several designated preset points WebEye SPD will automatically patrol the preset points with in a group. Users can easily make a monitoring group by gathering the above preset points. Firstly click the “New Group” button and the New Group configuration pop-up window will be activated like right figure. On this window, select the number where users want to make a new group or change the existing group.
9) Serial Port Configuration WebEye SPD has an RS232C interface ports for Audio device. WebEye SPD also support the specialized Audio Device for WebEye series called “Voice Messenger”. This is connected to Audio Device port physically and enabled at this menu.
11) Alarm Configuration Motion Detection Threshold: User set threshold for motion detection function. Threshold ‘0’ is the most sensitive state and ‘900’ is the dullest state. Alarm Parameters for E-mail / FTP Application: User defines image-recording conditions to WebEye, if WebEye detect events through motion detection function (MD Event) or external sensors (SID1 & SID2 Event). WebEye can record 2 frames for 2 seconds before the event and also for 2 seconds after the event.
Select Main Page: Administrator assigns a viewer as a main page that appears first when users access Webeye SPD. Administrator can select a viewer among 3 different ones such as “Default Viewer ”, “720×486 Viewer”, and “Server -Push Viewer”. 720×486 Viewer is to show the biggest image page to which users can not access with “Default Viewer” Viewer Editing : Viewer Page of WebEye SPD is designed for users to edit easily. Editable parts are as bellows.
(Appendix 1) Detailed Specifications of WebEye SPD-160 1. General CPU Flash memory RAM OS Video Channel 32bit RISC Embedded processor 8Mbyte 16Mbyte Embedded Linux NTSC or PAL video format are supported 1Ch.
3. Lens Specification F3.9mm to 62.4mm 16x Optical Lens Focal Length 8x Digital Zoom (Total 128x Zoom) Max. Relative Aperture Wide 1:1.4, Tele 1:2.7 Min. Focus Distance 1,000mm (Tele End) Min. Illumination 3.0 Lux/0.5 Lux. (Slow Shutter Mode) 4. Pan/Tilt Specification Pan Rotation Pan Speed Manual Preset Tilt Rotation Tilt Speed Manual Preset 360 continuous 0.8 to 120 /sec. (64 steps -speed) 0.8 to 240 /sec. (64 steps -speed) 0 to 90 0.8 to 120 /sec. (64 steps -speed) 0.8 to 180 /sec.
(Appendix 2) Frequently Asked Question 1. About WebEye’s Feature 1) What is WebEye? WebEye is a Web camera server. WebEye is consisted of 3 components as CCD module, Web server, and networking device. WebEye captures, processes, and transmits digital images through network. As WebEye itself operates as a Web server, it does not require other dedicated server connection as PC does. By installing WebEye itself at the desired site, you may monitor views from remote site.
user PC’s performance and network line capacity. WebEye can transmit to up to 100 users simultaneously. If 5 users are receiving 10 frames per second, the total frames that WebEye to transmit are 50 frames per second. In this case, WebEye transmits 50 per second from its viewpoint. And the total size of 50 frames’ images is under the network bandwidth.
5) When the network is consisted with only private IP addresses, can WebEye be connected at the network? WebEye can be connected to LAN having only private IP addresses as long as local users access WebEye. However the whole network can be down, if the network’s equipment such as a hub is not acceptable to support all the devices appropriate. Especially, this situation occurs if a lot of WebEyes are connected on a network of narrow bandwidth.
To solve this problem, user should remove and try to re-install WebEye control program as follows. Remove WebEye control program by clicking the right button and selecting ‘Remove’ menu. At a PC that uses Windows98 OS, the program is installed in the directory of C:\windows\Downloaded Program Files. And at a PC of Windows NT or 2000, it is in the directory of C:\winnt\Downloaded Program Files. Then, access again to WebEye and install Active-X Control program.
12) There is some problem to access WebEye. Sometimes I can access WebEye and sometimes not. How can it be solved? Mostly this problem occurs on Cable Modem, ISDN, and xDSL lines that use modems or routers. Those lines connect WebEye and ISP though their modems or routers, and the modems or routers are set to disconnect their connection while WebEye does not use lines. It is because ISP sets the condition on the modem or routers to prevent their lines from being loaded a lot.
(Appendix 3) Utilizing IP Addresses on Local Network 1. Introduction Most of our businesses are done via Internet, lately. We play with information by transmitting through e-mails and searching the world of Internet. IP address is what we utilize to access to the Internet. Currently used IP addresses are limited. And there are 5 classes networks in the world for now, and a network contains lots of IP addresses. A network can hold limited IP addresses. The numbers depend on network class.
Broadcast address: It is to broadcast to all devices that are connected on local network. Broadcast address is a destination for broadcasting and it is determined by calculating. All devices connected on local network have a same Broadcast address. Subnet Mask address: It is to divide a local network into two remote networks. Subnet Mask address roles as a border.
(Appendix 4) Updating WebEye SPD Firmware Warning This process is to update the current firmware that is already installed into your WebEye with a new updated firmware. If you are to begin the process, wait until the ‘Loading complete’ message appears. And during the process, do not give physical shock nor disconnect network and power. Otherwise, your WebEye can be damaged seriously, which may result inappropriate operation or operation failure.
2. Upgrade firmware with upgrading program (1) Practice upgrading program and select WebEye that you are going to update by clicking on IP address or MAC address in the list. When an IP address appears in the blanks of ‘Selected IP address’, key in the administrator’s password in the blank of ‘Administrator’s password’. Then click ‘Start’ button. (2) Click ‘Yes’ button to reboot WeyEye. (3) Click ‘OK’ button to start rebooting process.
(Appendix 5) WebEye SPD Physical Installation Guide 1. Contents Item Ceiling Suspension Bracket AC Adapter mounting Plate AC Adapter fixing screw M3 Camera fixing screw M3 Tapping screw M4 Safety wire Safety wire fixing bolt & nut Ceiling screw anchor Q’Y 1 1 6 1 3 1 2 3 Remarks Connector B’ D attached Use this item when necessary 2. WebEye SPD physical installation procedure . (1) Before installation, confirm strength of the location where the “Ceiling Suspension Bracket” is installed.
(6) Adapter installation : Adapter should be attached on the Ceiling Suspension Bracket. (7)-1 Fix the AC adapter on the included mounting plate (I) with 4 M3 screws (7)-2 Screw the two included M3 bolts to the side of mounting plate(J) leaving a margin of 1.2~2mm. Insert the assembled mounting plate to the side hall and pull it down. And fasten the two M3 bolts (8) Connect the camera cable(G) to camera body.
(Appendix 6) WebEye SPD Power Adapter Installation Guide 1. 12V Adaptor For WebEye SPD (SAC-24CK ) 1) Checking the Package Contents Check that the following items are included in the package.Adapter (1), Power Cord(1), Hook (2) 2) Installation Refer to Ceiling Suspension Bracket Guide (Appendix 5), when this adaptor is linked with Ceiling Suspension Bracket SM1600FP. Attach the Hook included the package to the building superstructure when this adaptor is used alone.
2. 12V Adaptor For WebEye SPD (SAC-1600NK) 1) Checking the Package Contents Check that the following items are included in the package.Adapter (1), Power Cord(1), Hook (2) 2) Installation Adaptor Refer to Ceiling Suspension Bracket Installation Guide (Appendix 5), when this adaptor is linked with Ceiling Suspension Bracket SM1600FP. Attach the Hook included the package to the building superstructure when this adaptor is used alone.
3. 12V Adaptor For WebEye SPD (SAC-1600PK) 1) Checking the Package Contents Check that the following items are included in the package. Adapter (1), Power Cord(1), Hook (2) 2) Installation Adaptor Refer to Ceiling Suspension Bracket Installation Guide (Appendix 5), when this adaptor is linked with Ceiling Suspension Bracket SM1600FP. Attach the Hook included the package to the building superstructure when this adaptor is used alone.