Specifications

Meter Selection Guide
Total Dissolved Solids
Meter Quick Guide
Total Dissolved Solids Meter Quick Guide
* Maximum 199.9 ppt depending on factor setting ** Maximum 500 ppt depending on factor setting
Models Parameters TDS Range Accuracy Cal. Points GLP Memory
Temperature
Display
Housing
Rating
Communication
Page
No.
Pocket Testers
PTTestr 35 pH/TDS/ºC/ºF
100 to 1000 ppm
1.00 to 10.00 ppt
±1 % full scale 2 manual Yes IP67 Pg 70
TDSTestr 11+ TDS/ºC/ºF
.. to 200.0 ppm
.. to 2000 ppm
.. to 10.00 ppt
±1 % full scale 2 Yes IP67 Pg 38
TDSTestr 11 TDS/ºC/ºF
.. to 2000 ppm
.. to 10.00 ppt
±1 % full scale 3 Yes IP67 Pg 38
EcoTestr TDS High TDS .. to 10.00 ppt
±1 % full scale
(±2 % above
5 ppt)
1 IP67 Pg 40
EcoTestr TDS Low TDS .. to 1990 ppm ±1 % full scale 1 IP67 Pg 40
Handheld Meters
CyberScan PCD 650
pH/ORP/Ion/
Conductivity/TDS/
Salinity/Resistivity/
Dissolved Oxygen/ºC/ºF
.. to 2.000 ppm
2.000 to 300.0 ppm
300.0 ppm to 4.000 ppt
4.000 to 40.00 ppt
40.00 to 500.0 ppt
±1 % full scale
+ 1 LSD
5 Yes 500 Yes IP67 LED RS232C, IrDA Pg 72
CyberScan PC 650
pH/ORP/Ion/
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
.. to 2.000 ppm
2.000 to 300.0 ppm
300.0 ppm to 4.000 ppt
4.000 to 40.00 ppt
40.00 to 500.0 ppt
±1 % full scale
+ 1 LSD
5 Yes 500 Yes IP67 LED RS232C, IrDA Pg 73
CyberScan CD 650
Conductivity/TDS/
Salinity/Resistivity/
Dissolved Oxygen/ºC/ºF
.. to 2.000 ppm
2.000 to 300.0 ppm
300.0 ppm to 4.000 ppt
4.000 to 40.00 ppt
40.00 to 500.0 ppt
±1 % full scale
+ 1 LSD
5 Yes 500 Yes IP67 LED RS232C, IrDA Pg 73
CyberScan COND 610
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
.. to 2.000 ppm
2.000 to 300.0 ppm
300.0 ppm to 4.000 ppt
4.000 to 40.00 ppt
40.00 to 500.0 ppt
±1 % full scale 5 Yes 500 Yes IP67 LED RS232C, IrDA Pg 43
CyberScan COND 600 Conductivity/TDS/ºC/ºF
.. to 2.000 ppm
2.000 to 300.0 ppm
300.0 ppm to 4.000 ppt
4.000 to 40.00 ppt
40.00 to 200.0 ppt
±1 % full scale 5 Yes 500 Yes IP67 LED RS232C, IrDA Pg 43
CyberScan CON 400 Conductivity/TDS/ºC/ºF .. to 199.9 ppt * ±1 % full scale 5 Yes 50 Yes IP67 Pg 44
CyberScan CON 110 Conductivity/TDS/ºC/ºF .. to 199.9 ppt * ±1 % full scale 5 100 Yes IP54 RS232C Pg 45
CyberScan CON 11 Conductivity/TDS/ºC .. to 199.9 ppt * ±1 % full scale 5 50 Yes IP54 Pg 45
TDS 6+ TDS/ºC .. to 199.9 ppt * ±1 % full scale 5 Yes IP54 Pg 46
Bench Meters
CyberScan PCD 6500
pH/ORP/Ion/
Conductivity/TDS/
Salinity/Resistivity/
Dissolved Oxygen/BOD/
OUR/SOUR/ºC/ºF
.. to 500 ppt
0.5 % full scale
+ LSD
5 Yes
1000 per
parameter
Yes
Internet/intranet,
RS232C, USB,
IrDA, SD card
Pg 79
CyberScan PC 6500
pH/ORP/Ion/
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
.. to 500 ppt
0.5 % full scale
+ LSD
5 Yes
1000 per
parameter
Yes
Internet/intranet,
RS232C, USB,
IrDA, SD card
Pg 80
CyberScan PC 6000
pH/ORP/Conductivity/
TDS/Salinity/Resistivity/
ºC/ºF
.. to 500 ppt
0.5 % full scale
+ LSD
5 Yes
1000 per
parameter
Yes
Internet/intranet,
RS232C, USB,
IrDA, SD card
Pg 80
PC 2700
pH/ORP/Ion/
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
0.050 ppm to 500 ppt
(@ TDS factor 1.00)
±1 % full scale 5 Yes 500 Yes RS232 Pg 81
PC 700
pH/ORP/Conductivity/
TDS/Resistivity/ºC/ºF
.. to 100.0 ppt @ 0.5 fact
(200.0 @ 1 factor)
±1 % full scale 5 100 Yes Pg 82
CyberScan CON 6000
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
.. to 500 ppt
0.5 % full scale
+ LSD
5 Yes
1000 per
parameter
Yes
Internet/intranet,
RS232C, USB,
IrDA, SD card
Pg 50
CON 2700
Conductivity/TDS/
Salinity/Resistivity/ºC/ºF
0.050 ppm to 500 ppt
(@ TDS factor 1.00)
±1 % full scale 5 100 Yes RS232C Pg 51
CON 700 Conductivity/TDS/ºC/ºF
.. to 100.0 ppt @ 0.5 fact
(200.0 @ 1 factor)
±1 % full scale 5 50 Yes Pg 52
page | 06
Selection Guide