User Manual
8
WWW.WEBER.COM
®
(1)
(2)
(3)
REMOVE CONTROL PANEL AND BURNER CONTROL KNOBS
You will need: Phillips screwdriver.
1) Remove control knobs.
2) Remove screws with a Phillips screwdriver
3) Pull up igniter button until it sticks in the up position and remove control panel from
grill.
4) Replace control panel when Leak Check is completed.
SPIRIT E/SP-
210 & 310
WARNING: You should check for gas leaks every time you
disconnect and reconnect a gas fi tting.
Note: All factory-made connections have been thoroughly checked for gas leaks. The
burners have been fl ame-tested. As a safety precaution however, you should recheck
all fi ttings for leaks before using your Weber
®
Gas Barbecue. Shipping and handling
may loosen or damage a gas fi tting.
WARNING: Perform these leak checks even if your barbecue
was dealer- or shop-assembled.
You will need: a soap-and-water solution, and a rag or brush to apply it.
Note: Since some leak test solutions, including soap and water, may be slightly
corrosive, all connections should be rinsed with water after checking for leaks.
If your grill has a side burner make sure the side burner is off.
To perform leak checks: open cylinder valve by turning the cylinder valve hand-wheel
counter-clockwise.
WARNING: Do not ignite burners when leak checking.
Check for leaks by wetting the connections with the soap-and-water solution and
watching for bubbles. If bubbles form or if a bubble grows, there is a leak.
DANGER
Do not use an open fl ame to check for gas leaks. Be sure
there are no sparks or open fl ames in the area while you
check for leaks. Sparks or open fl ames will result in a fi re or
explosion, which can cause serious bodily injury or death
and damage to property.
CHECK FOR GAS LEAKS
GAS INSTRUCTIONS
(1)
(2)
(3)
(4)
*The grill illustrated may have slight
differences than the model purchased.
SPIRIT E/SP-
210 & 310
Check:
1) Hose-to-manifold connection.
2) Regulator-to-Cylinder connection.
WARNING: If there is a leak at connection (1), retighten the
fi tting with a wrench and recheck for leaks with soap and water
solution.If a leak persists after retightening the fi tting, turn OFF
the gas. DO NOT OPERATE THE GRILL. Contact the Customer
Service Representative in your area using the contact
information on our web site. Log onto www.weber.com
®
.
Check:
3) Valves-to-manifold connections.
4) The hose-to-regulator connection.
WARNING: If there is a leak at connections (2), (3) or (4),
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site. Log onto www.weber.
com
®
.
When leak checks are complete, turn gas supply off at the source and rinse connections