LEAK CHECK PREPARATION
CHECKTHAT ALL BURNER VALVES ARE OFF
Valves are shipped in the OFF position, but you should check to be sure that they are
turned off. Check by pushing down and turning clockwise. If they do not turn, they are
off. Proceed to the next step. If they do turn continue turning them clockwise until they
stop, then they are off. Proceed to the next step.
REHOVE CONTROL PANEL AND BURNER CONTROL KNOBS
You will need Phillips screwdriver.
1) Remove control knobs.
2) Remove screws with a Phillips screwdriver
3) Pull up igniter button until it sticks in the up position and remove control panel from
grill.
4) Replace control panel when Leak Check is completed.
SPIRIT E/SP-
210 & 310
CHECK THE FLEXIBLE HOSE TO MANIFOLD CONNECTION
The Natural gas hose has been attached during the manufacturing process. We
do recommend thatthe hoseto gas manifold connection be leaktested, following
guidelines in this Owners Guide, priorto barbecue operation.
Check:
1) Hoseto manifold connection.
/K WARNING: If there is a leak at connection (1), retighten the
fitting with a wrench and recheck for leaks with soap and water
solution. If a leak persists after retightening the fitting, turn OFF
the gas. DO NOT OPERATE THE GRILL. Contact the Customer
Service Representative in your area using the contact
information on our web site. Log onto www.weber.com ®.