SDS
Safety data sheet
According to Regulation (EU) No 2015/830
Product name
Date of issue
: Weber Fire starter
: 2020-12-15
Page 4/10
INFO CARE SDS
Replaces issue dated : 2020-06-08
SECTION 8 EXPOSURE CONTROLS/PERSONAL PROTECTION
Handling : Handle in accordance with good occupational hygiene and safety practices in well-ventilated
areas. Keep away from sources of ignition — No smoking. Ground/bond container and receiving
equipment. Use explosion-proof electrical/ventilating/lighting equipment. Electrostatic discharge
may cause fire. Ensure electrical continuity by bonding and grounding (earthing) all equipment. Do
not breathe vapour. Avoid contact with skin and eyes. Wear protective clothing.
7.2. Conditions for safe storage, including any incompatibilities
Storage : Keep frost-free, in a cool, dry and well-ventilated place. Keep away from oxidizing agents.
Recommended packaging : Keep only in the original container.
Non recommended
packaging
: Steel (except stainless steel).
7.3. Specific end use(s)
Use : Use only as directed.
8.1. Control parameters
Occupational exposure
limits
: Occupational exposure limits have not been established for this product. Derived no-effect levels
(DNEL) have not been established for this product. Predicted no-effect concentrations (PNEC) have
not been established for this product.
Workplace exposure limits (mg/m³):
Chemical name Country TWA 8 hour
(mg/m3)
STEL 15 min
(mg/m3)
Comments Source
Hydrocarbons, C10-C13, n-alkanes,
isoalkanes, cyclics, < 2% aromatics
1200 - - CEFIC-HSP
A
Predicted no-effect concentration (PNEC):
Chemical name Route of exposure Fresh water Marine water
Distillates (Fischer- Tropsch) C8-26
branched and linear
Sediment 2,06 mg/kg
10 mg/l
1,68 mg/kg
0,01 mg/kg food
STP
Soil
Oral
8.2. Exposure controls
Engineering measures : Use only in well-ventilated areas. Comply with standard precautionary measures for working with
chemicals.
Hygienic measures : When using do not eat, drink or smoke.
Personal protective equipment:
The efficiency of personal protective equipment depends among other things on temperature and degree of ventilation. Always get
professional advice for the particular local situation.
Body protection : Use of specific protective industrial clothing is not required under normal conditions of use. In
case of large scale exposure wear suitable protective clothing, overalls or suit, and similar boots.
Suitable material: nitril. Indication of permeation breakthrough time: 6 hours.
Respiratory protection : Take care of sufficient ventilation. Wear suitable respiratory protection in case of large scale
exposure.
Hand protection : Under normal conditions of use specific gloves are not required. Wear appropriate gloves in case of
frequent or prolonged use and in case of large scale exposure. Suitable material: nitril. ± 0,5 mm.
Indication of permeation breakthrough time: 6 hours.
Eye protection : Wear appropriate safety glasses when there is danger of possible eye contact.