4.1 Supply Sea Water
The delivery of sea water of the open loop cooling circuit has to meet the speci cation listed in the table.
engine speed
Engine: 98 - 105 kW Engine: 49 - 76 kW
Fresh water pressure
HO cooling system
(at pump outlet Line)
Water ow
HO system
Fresh water pressure
SO cooling system
(at pump outlet Line)
Water ow
SO system
[ rpm] [ bar ] [ l/min ] [ bar ] [ l/min ]
1500 0.25 13.40 0.18 11.00
2000 0.26 17.50 0.22 12.20
2500 0.38 21.40 0.20 13.00
3000 0.58 26.20 0.25 15.00
3500 0.77 32.00 0.35 19.00
4000 0.98 36.70 0.51 24.00
4500 1.22 40.70 0.69 29.50
5000 1.49 47.20 0.92 35.00
5500 1.85 54.60 1.19 41.00
6000 2.20 61.60 1.53 46.50
6500 2.62 67.80 1.84 53.00
7000 3.00 71.70 2.20 59.00
7500 3.39 74.00 2.51 63.50