Technical data
HL 90
52
Heater HL 90
Type HL 90
ECE homologation EMC: E1 04 1086
Heater: E1 00 0017
Model Air heater with rotation evaporator
Heating current Full load kW
Part load kW
9
6.5
Fuel Diesel/heating oil EL
Fuel consumption Full load kg/h (l/h)
Part load % by vol.
1.00 (1.20)
0.71 (0.86)
Rated voltage V- 12 or 24
Operating voltage V- 10 ... 14.5 or 20.5 ... 29
Rated power consumption Full load W
(not in starting operation) Part load W
110
80
Max. ambient temperature during operation:
- Heater °C
- Control unit °C
- Metering pump °C
-40 ... +50
-40 ... +85
-40 ... +40
Max. storage temperature:
- Heater °C
- Control unit °C
- Metering pump °C
-40 ... +85
-40 ... +85
-40 ... +85
Max. hot air inlet temperature °C +30 max.
Delivery rate for hot air
against 0.5 mbar at full load m
3
/h
against 0.25 mbar at part load m
3
/h
280
195
CO
2
in exhaust gas (at full load):
- Permitted function range % by vol. 7 ... 10
CO in exhaust gas - In still air % by vol.
- At 100 km/h % by vol.
0.1 max.
0.2 max.
HC in exhaust gas (at rated load and in still air) % by vol. 0.01 (100 ppm) max.
NOx in exhaust gas (at rated load and in still air) % by vol. 0.02 (200 ppm) max.
Soot index - Bacharach method 4.0
Heater dimensions: Length mm
(tolerance ±3 mm) Width mm
Height mm
Metering pump dimensions: Length mm
(tolerance ±3 mm) Width mm
Height mm
Control unit 1561 dimensions: Length mm
(tolerance ±3 mm) Width mm
Height mm
650
235
260
113
40
35
97
102
36
Weights: Heater kg
Control unit kg
Metering pump kg
13
0.30
0.35
HL90 EA_de_en_fr.book Page 52 Wednesday, June 5, 2013 10:17 AM