Operating instructions

Diagnosis in the Event of a Fault Shutdown of Thermo 90
Check fuses and electrical connections.
If the heater is activated by the switch or the timer with 3
time settings, the different types of malfunctions are indi-
cated by coded flashing signals via the operation indicator
light during the after-run period of the heater.
After five short signals have been emitted, the long flash-
ing pulses can be counted:
1x No start (after 2 start-up attempts)
2x Flame extinction (recurrent >5)
3x Undervoltage
4x Premature flame detection
5x Flame detector interruption or
flame detector short circuit
6x Temperature sensor interruption or
temperature sensor short circuit
7x Metering pump interruption or
metering pump short circuit
8x Blower motor interruption or
blower motor short circuit
blower motor incorrect speed
9x Pencil-type glow plug interruption or
pencil-type glow plug short circuit
Thermo 90 / Thermo 90 S
19