Technical data
Electrical connections Thermo 90 S / Thermo 90 ST
50
9.5. Thermo 90 S control module
The control module offers protection type IP6K4K if it is installed in the 
position shown in Figure 13.
9.6. Thermo 90 ST control module
The control module offers protection type 6K9K if it is installed in the 
position shown in Figure 14.
9.7. To set the regulating temperatures 
Thermo 90 S / Thermo 90 ST
If the “Engine on”/”Engine off” signal (terminal D+) is applied to control 
module plug X12 contact 7 (Thermo 90 S) or plug X8 contact 7 
(Thermo 90 ST), different regulating thresholds take effect 
If the terminal D+ signal is not applied, the temperatures are the same 
as those at “Engine off”.
NOTE:
The selected regulating pause temperature of the heater should be 
lower than the opening temperature of the radiator thermostat.
Fig. 13: Thermo 90 S (from 03/97) control module, installation position
Fig. 14: Thermo 90 ST control module, arbitrary installation position
24 V
XXXXXXX_.XXXXX
Nominal 
temperature at 
the sensor
Regu-
lating 
pause
Switch on again 
after regulating 
pause
“Engine on” 72 °C 82 °C 67 °C
“Engine off” 80 °C 90 °C 75 °C