Technical data
Fuel supply Thermo 90 S / Thermo 90 ST
42
6 Fuel supply
The fuel is taken from the vehicle fuel tank or from a separate fuel tank.
The values for the maximum pressure at the fuel extraction point are 
shown in the table below. 
Only for ADR:
 The statutory regulation of ADR (Accord européen relatif 
au transport international des marchandises dangereuses par route) 
governing fuel tanks, part 9 para. 9.2.4.7, must be adhered to.
NOTE:
A sign must be affixed to the fuel filler neck warning that the heater must 
be switched off before refuelling.
Permissible fuel inflow 
height H (m)
At max. pressure (bar) 
in fuel line
0.00 0.2
1.00 0.11
2.00 0.03
Maximum fuel intake 
height S (m)
At max. negative pressure 
(bar) in the fuel tank
0.00 -0.10
0.50 -0.06
1.00 -0.02
Fig. 3: Fuel supply
l
1
 + l
2
 ≤ 10 m
l
2
 ≤ 1.2 m
l
2
 ≤ 8.8 m