Technical data

Thermo 90 S / Thermo 90 ST Installation
39
3 Installation
IMPORTANT
The water heater must be installed outside the passenger cabin.
The requirements of the latest version of the ADR must also be
observed for the installing the heater into vehicles used to transport
hazardous substances.
NOTE:
If the vehicle manufacturer has issued instructions, they must be
followed.
3.1. Installation site / Installation position
The heater must be installed in as low a position as possible to allow the
heater and circulating pump to be bled automatically. This is particularly
important as the circulating pump is not self-priming.
3.2. To install the heater
The heater must be secured with at least three M8 screws. The screws
must be tightened with a torque of 18 Nm.
3.3. Model plate
The model plate must be positioned so that it cannot be damaged
and must be clearly legible when the heater is installed (otherwise a
duplicate model plate must be used).
Inapplicable years must be erased from the model plate.
Fig. 1: Permitted installation positions for the Thermo 90 S /
Thermo 90 ST