Technical data

Thermo 230 / 231 / 300 / 301 / 350 6 Functional Checkouts
603
6.3.4 Igniter Box Check
NOTE
The igniter box may also be tested using the PC heater
diagnosis (component test).
WARNING
High voltage; 20.000 volts arcing across the igniter
electrodes.
CAUTION
Do not apply voltage to igniter box without electrodes.
Check
apply 24 V as shown on figure
normal condition: spark between electrodes.
6.3.5 Fuel Pump Check
6.3.5.1 Fuel Pump Check on Heaters with Control Unit
1572
A test gauge is required for performing the test. Such a
gauge (with a range from 0 to 15 bar) can be procured
from your authorized Spheros dealer.
The fuel pump and the fuel hoses must be replaced every
5 years.
CAUTION
The electronic ignition coil must be removed for safety
reasons.
Check
remove igniter box (refer to 9.2.7.1).
remove nozzle.
screw on tester.
cover flame sensor.
switch on heater.
after approximately 13 sec. pump pressure is
indicated (refer to diagram).
switch off heater.
unscrew tester.
CAUTION
Do not damage nozzle bore.
screw in nozzle and torque with 20 Nm.
install igniter box (refer to 9.2.7.2).
Igniter electrodes 20.000 V
NOTE
Igniter box (black
connector cover)
only in combination
with control unit
1572
Igniter electrodes 20.000 V
NOTE
Igniter box
(green connector cover;
mechanically coded)
in combination with
control unit
1572D and
also with
control unit
1572
2500 3000
8
8,5
9
9,5
10
10,5
11
4000 5000 6000 7000 8000 8500
Thermo 350
Thermo 300/301
Thermo 230/231
Speed (min
-1
)
Pump pressure in relation to speed
Pump pressure (bar)