Technical data
Thermo Top Z/C
9 Repair
901
9. Repair
9.1 General
This section describes the repairs that may be performed
on the heaters Thermo Top Z and Thermo Top C when
removed. Any further disassembly will void the warranty.
After repairs a functional test must be performed.
9.1.1 Work on Components after Disassembly
CAUTION
All gaskets located between disassembled components
must always be discarded and replaced.
9.1.1.1 Cleaning
• All components disassembled must be cleaned.
• Sealing compound on components must be carefully
and completely removed using suitable means.
9.1.1.2 Visual Inspection
• Inspect all components for damages (cracks,
deformation, wear, etc.) and replace as required.
• Inspect connectors and wiring for corrosion, loose
contacts, wrong crimping, etc. and repair as required.
• Inspect connector terminal for corrosion and contacts
for security.