Web Mountain Technologies UPB Timer (TIM-01) Version 3 Revised May 10, 2007. For the latest revision, see www.webmtn.com/support/docs/TIM-01.
Web Mountain Technologies Table of Contents 1 Summary 2 How it works 3 Timer Buttons 4 Quick Start – Scheduled Programs 5 Quick Start – Countdown Timer 6 UPB Operations 7 On and Off Programs 8 Triggers 9 How to Program the UPB Timer 10 Immediate Run 11 Reset 12 Emergency Mode 13 Random Timers 14 Trouble Shooting 15 Support 16 Warranty 17 Other UPB Products UPB Timer (TIM-01) Version 3 1 1 1 2 3 4 5 5 5 11 11 12 12 12 13 14 14
User Manual for the UPB Timer (TIM-01) Version 3 1 Summary The TIM-01 UPB Timer is one of the most advanced standalone timer-controllers on the market today. It can easily be programmed to control individual UPB devices or UPB scenes either manually or on a timed basis. The Timer can control up to 99 programs and with the Timer’s buttons, you can manually control 4 scenes.
Web Mountain Technologies Quick Tour 1. LCD Readout. All output is displayed here. Normally this area will show the time of day, the date and the day of the week. 2. UP/DOWN. These two buttons are mainly used to select different values for the various fields and attributes that can be set. These buttons can also operate as Immediate Run buttons or as Panic buttons. See the following sections for more details about these alternative uses. 3. FUNCTION.
TIM-01 User Manual • Set up a program to Activate the Link Push the MENU button until the SET screen is displayed. o o o o o o o o o • Set up a program to Deactivate the Link o Push the MENU button until the SET screen is displayed. o o o o o o o o o • Use the RIGHT button to move to the hour field. The NEW field will automatically change to the next available program number. If this is the first time you have set up any programs, the field will change to P01.
Web Mountain Technologies o o o o o o o o Use the RIGHT button to move to the first Link field. The NEW field will automatically change to the next available trigger number. If this is the first time you have set up any triggers, the field will change to T01. Use the UP/DOWN buttons to select the Link (in our example L040) that will indicate to the timer that a count-down operation is to begin.
TIM-01 User Manual The only way the TIM-01 Timer can control UPB devices is by issuing Link commands, therefore every device to be controlled must be associated with one or more Links and the behavior of each of those Links must be defined for each device to be controlled by that Link. UPB devices and Links cannot be adequately set up by manual means – you must use the Web Mountain NetPlace server, the free download program UPStart or some other programming tool to set up the modules and Links. See www.
Web Mountain Technologies o o o o o o o o o o o o o o • Setting Up Sunset and Sunrise Based Programs: o • You can set up Sunset or Sunrise timers, or timers that vary from Sunset or Sunrise by a certain amount. You get to this variation of the SETP screen by cycling through 6PM (to get to sunSET) or cycling through 6AM (to get to sunRISe). When SET (or RIS) is flashing, use the RIGHT button to get to the + or – sign (default is +).
TIM-01 User Manual o o o o o o o o o o o o • Triggers to suspend or enable programs: o o o o o o • o o o o 7 There are 10 fields that can be set on this screen: program or trigger, program or trigger number, triggering Link, triggering activity, hours/minutes value, h or m, minutes/seconds value, L or P, program number and ENAB/SUSP/NEXT.
Web Mountain Technologies o o o • SET TIME (Push MENU button until SETTIM shows) o o o o o o o o o o o o • There are 7 fields that can be set on this screen: hour, minute, AM/PM, month, day, year and Y or N for Daylight Savings Time. The hour field will be flashing. Use UP or DOWN buttons to set hours (the Timer will update AM/PM as it crosses midnight or noon). Use RIGHT and LEFT buttons to cycle between hours, minutes, AM/PM, month, day, year and DSTY/N (whichever field is selected flashes).
TIM-01 User Manual o o o o • The TIM-01 UPB Timer can operate as an Emergency or Panic button, turning on all lights in the house to indicate an emergency situation. The user defines the EMERGENCY action by creating a UPB Link that performs according to the user’s desires (see the preceding section on UPB Operations for more details on setting up UPB Links). The Timer can be set to one of three different types of Emergency modes: ENTER – The Timer will only perform the EMERGENCY Link when in RUN mode.
Web Mountain Technologies o o • VACATION (Push FUNCTION button until the following screen shows): o o o o • Vacation mode is meant to give your home a lived in look even when you are away. For that reason, the Timer will run all Normal, Random and Vacation programs and will operate all Normal and Vacation triggers when in Vacation mode.
TIM-01 User Manual o • LOCK MENU (Push FUNCTION button until the following screen shows): o o o o o • The LOCK MENU function allows you to disable the MENU button. If you want to make sure that a casual user does not accidentally, or maliciously, change any of your settings, program definitions or triggers, you can use this function to keep the MENU button from functioning at all. From this screen use the UP/DOWN buttons to change the top N to Y if you want to lock the MENU button.
Web Mountain Technologies At this point, if you push the MENU button or the FUNCTION button rather than the ENTER button, the Timer will go to the next screen with all settings exactly the same as before the Reset procedure was started. If, however, you hit ENTER here, the Timer will reset all values (except Time and Date) to default values and show this screen: If you push ENTER here, the Timer will utilize the 2007 law to determine Daylight Saving Time changes.
TIM-01 User Manual You may have suspended a program or set it up to be skipped. Use the SET screen to see the definition of the program that is not working. If there is a small s or small n next to the program number, the program has been suspended (s) or skipped (n). If you already have a trigger set up to enable the program in question, use the RUNPROG screen to run that trigger.
Web Mountain Technologies 16 Warranty Web Mountain Technologies, Incorporated (WMT) warrants to the original purchaser that each TIM-01 UPB Timer delivered shall be free from defects in material or workmanship at time of shipment, and that each Timer delivered will meet the published specifications for a period of one year as measured from the date of original shipment.