Specifications
EN.PM.UM13 20140227 Earth Networks Weather Station Page 17 of 47
o Staffedlocationtoensureequipmentisoperatingyear‐round
o Year‐roundpowerandinternetconnection
o Asecureareawhereequipmentwillnotbetamperedwithorturnedoff
o Adequateventilation(equipmentmustnotgetover‐heated)
InstallingOutdoorComponents
Therearethreebasicstepsafterensuringtheselectedlocationfulfillssitecriteria:
1. InstallationoftheMast
2. SecuringtheSensorstotheMast
3. ConnectingtheWeatherSensorCablesandGrounding
Datacablesarenotratedformovementbelow+15ºF/‐9ºC.EarthNetworksdoesnot
recommendinstallingiftheoutdoortemperatureislessthan+15ºF/‐9ºC.