NOTES:
WeatherBug recommends that you tape the connector ends together before
running them inside the building (tape them fully to prevent damage or loosening
individual wires). Do not cut connectors off. A single loose cable connection
can cause system errors.
Route Data Cable through 1¾ inch outside diameter conduit on exterior of
building.
Seal building hole and both ends of conduit using caulk/putty.
Because the WeatherBug Weather Station Data Cable is UV-rated, conduit is not
required along the length of the mast, but should be used along the length of the
building.
Use the shortest route possible when running cables inside the building.
The Data Cable ends at the BBB. Excess cable should be coiled, tied and stored
near the BBB.
12. Securely attach a grounding cable to a metal part of the mast. The mast MUST be
grounded to protect against lightning and static charge build-up. The ground wire
must be connected to an appropriate location (consult a school or district electrician
to ensure proper grounding).
IMPORTANT: Ground cable and installation must conform to all applicable local
building codes. The mast must be grounded to an "earth" ground.
The buyer/installer is responsible for this procedure and for ensuring that materials and
methods conform to all applicable building codes.