Specifications
13
sump | back-up & simple sump systems
WSM3300
ADVANCED NOTIFICATION BACK-UP SYSTEM
PERFORMANCE
Model Switch Type Construction Limited Warranty HP Discharge Head 5 ft. 10 ft. 15 ft. 20 ft.
WSM3300 Dual Float Thermoplastic 2 Years 1/2 Gallons/Hour 2800 2300 1500 400
4000300020001000 5000
25
20
15
10
5
0
TOTAL DYNAMIC HEAD (FT.)
FLOW RATE IN GPH
WSM3300
12 VOLT BATTERY BACK-UP SYSTEM WITH ADVANCED NOTIFICATION
S YSTEM INCLUDES:
• Sump Minder microprocessor continuously monitors battery status and self tests the back-up sump pump every 14 days
• Sends a voice alert to up to 3 phones in the event of back-up pump activation, high water, low battery charge, self-diagnosed
pump problem, and more
• Provides up to 92 hours** of basement protection during a power outage
• Easily programmed with the built-in LCD display screen and panel buttons
• Quick connection to a standard telephone line to send voice alert messages
• Double fl oat switch for extra reliable, automatic operation
• Requires a deep cycle, wet cell or maintenance free, 12 V battery (not included)
• Back-up pump max. fl ow is 3300 gallons per hour; 2300 GPH at 10 ft. of discharge lift
• Recommended for use in fi nished basements, basements with high value items,
protecting second homes, monitoring rental property, people that frequently travel or
away from home for extended periods of time
DEEP CYCLE BATTERY SIZE
IF YOUR SUMP PUMP RUNS...
1X EVERY MINUTE 1X EVERY 5 MINUTES 1X EVERY 10 MINUTES
HOURS OF PROTECTION
12 Hr 53 Hr 92 Hr
23 Hr 100 Hr 172 Hr
40 A-Hr Battery
75 A-Hr Battery
** Using a 40 amp-hour deep cycle battery and the back-up pump with a 10 ft. lift:. Results may vary.