Specifications

Notas
Installation
1. Install pump in a sump pit with
minimum size as shown in Figure 1.
Construct sump pit of tile, concrete,
steel or plastic.
2. The unit should be located and rest
on a solid, level foundation. Do not
place pump directly on clay, earth,
gravel or sandy surface. These
surfaces contain small stones, gravel,
sand, etc. that may clog or damage
the pump and cause pump failure.
Flood risk. If flexible discharge hose is
used, make sure pump is secured in
sump pit to prevent movement. Failure
to secure pump could allow pump
movement and switch interference and
prevent pump from starting or
stopping.
3. Thread check valve (not included)
into pump body carefully to avoid
stripping or cross threading. Do not
use pipe joint sealant.
4. Connect 1-1/4” (minimum) rigid pipe
to check valve.
Support pump and piping when
assembling and after installation.
Failure to do so could cause piping to
break, pump to fail, etc. which could
result in property damage and/or
personal injury.
5. Protect electrical cord from sharp
object, hot surfaces, oil and chemicals.
Avoid kinking the cord and replace
damaged cords immediately.
6. Position Pump switch AWAY from
the inlet so switch is clear from
incoming water (See Figure 1).
7. A sump pit cover must be installed
to prevent debris from clogging or
damaging the pump.
General Safety
Information
Do not use to pump
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in a
flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or property damage could result.
This pump is not designed to handle
salt water, brine, laundry discharge or
any other application which may
contain caustic chemicals and/or
foreign materials. Pump damage could
occur if used in these applications and
will void warranty.
All wiring must be performed by a
qualified electrician.
If the basement has water or
moisture on the floor, do not
walk on wet area until all
power is turned off. If the shutoff box
is in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.
A backupsystem should be used. Call 1-
800-237-0987 for backup model
number.
23-Sp
2
Operating Instructions And Parts Manual
CDUCAP Series
Operation
Always disconnect the power
source before attempting to
install, service, relocate or
maintain the pump. Never touch sump
pump, pump motor, water or discharge
piping when pump is connected to
electrical power. Never handle a pump
or pump motor with wet hands or when
standing on wet or damp surface or in
water. Fatal electrical shock could occur.
1. A ground fault circuit interrupter
(GFCI) is required.
Risk of electrical shock! This pump is
supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
the risk of fatal electrical shock.
Never cut off the round grounding
prong. Cutting the cord or plug will
void the warranty and make the pump
inoperable.
2. This pump is only for use on 120 Volt
(single-phase), 60 hz, 15 amp service
and is equipped with a 3-conductor
cord and 3-prong, grounding type
plug. Insert the switch cord plug
directly into a 120 volt outlet.
3. Insert the pump power cord plug
directly into the back of the water
sensor cord plug (Figure 2).
www.waynepumps.com
TEST
RESET
Figure 2 – Switch Genius™ Water Sensor
Working surface of
sensor to be kept
free of foreign
material.