MAINTENANCE SCHEDULE (continued)
WEEKLY (continued):
2. Inspect the burner head for accumulation of ashes. If ashes are present, clean immediately. Ashes in the
burner head can cause the burner to misfire. Inspect the interior walls of the firebox and scrape off any sol-
ids or creosote buildup in accordance with NFPA® 96.
3. Inspect the product door and firebox door gaskets. Replace if damaged or leaking.
4. The flue shall be inspected weekly for the following conditions in accordance with NFPA® 96:
a. Residue that might begin to restrict the vent or create an additional fuel source. The flue or chim-
ney should be cleaned before these conditions exist.
b. Corrosion or physical damage that might reduce the flue’s capacity to contain effluent. The flue or
chimney shall be repaired or replaced if any unsafe condition is evident.
5. The combustion chamber shall be scraped clean to its original surface once each week and shall be inspect-
ed for deterioration or defects.
Possible creosote buildup on
interior walls of firebox.
Ashes present in the burner head.
Product door gasket.