Sizing Guide
Suction
Lift (ft)
Suction
Pipe Size
Discharge
Pipe Size
Discharge
Distance (Ft)
Rise (Ft)
PSI
Required
GPM
Delivered
WLS75 3/4 HP
0 2" 1 1/2" 100 5 30 28
5 2" 1 1/2" 125 10 30 21
10 2" 1 1/2" 150 15 30 12
WLS100 1 HP
0 2" 1 1/2" 100 5 30 30
5 2" 1 1/2" 125 10 30 21
10 2" 1 1/2" 150 15 30 12
WLS150 1 1/2 HP
0 2" 1 1/2" 100 5 30 35
5 2" 1 1/2" 125 10 30 26
10 2" 1 1/2" 150 15 30 17
WLS200 2 HP
0 2" 1 1/2" 75 5 30 49
5 2" 1 1/2" 85 10 30 40
10 2" 1 1/2" 95 15 30 31
Install pump as close to water source as possible.
Do not reduce suction size piping
Do not reduce discharge size piping prior to branch/outlet area
Provide suction pipe with strainer protection without restricting water flow
Install check or foot valve on suction side
Provide adequate wire size for length of wiring distance and motor size.
The above flow rates are calculated with steel pipe. For better performance use PVC pipe.
WLS LAWN PUMP - SAMPLE APPLICATIONS