Owner`s manual
22
Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.
You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com
Detent Pin
Adjustment Screw
TO AVOID INJURY, NO ONE SHOULD
CROSS THE PATH OF A MOVING DOOR!
NOTE: If Step 36 was completed, skip this
step.
NOTE: The door must be in its fully closed
position and the Disconnect Handle must be
in the Motor Operated Position (upper
position) to initiate the install routine.
NOTE: Install routine will not run if Safety
Sensors are not aligned (Only if required
installation).
Press and hold the Profile Button for
five (5) seconds. The Opener will beep
twice, release the Profile Button, indicating
the activation of the install routine.
When the door moves to the desired upper
limt, press and hold the Up/Down Button on
the Wall Station until the door stops. Next,
the door will close completely. The Up/Down
button (when unit is closed) can be
activated by pressing center of flip cover.
Next, the door will go through one more Up/
Down cycle. Once this is complete, the door
limits are set and the installation is
complete.
Alternately, once an install routine has been
successfully completed, disconnect door
and manually move to desired upper limit.
Re-connect door and press and hold the
profile button for five (5) seconds.. The
door will close, open and close to complete
the install routine with the new upper limit.
The amount of pressure the Opener
uses to pivot the Motor downward is
preset at the factory via the Detent Pin
Adjustment Screw.
Due to variations in door installations,
a Detent Pin adjustment may need to
be made in order for proper pivoting of
the Motor.
IMPORTANT! For system security: the
Motor is designed to pivot down after the
door closes completely. If the Motor does
not pivot or pivots too soon, the Detent Pin
Adjustment Screw may need to be adjusted
in order for the door lock feature to work
properly.
Adjusting Detent
Install Routine
(Custom Upper Limit)
Tools Needed:
Flat Tip
Screwdriver
Profile
Button
Up/Down
Button
Tools Needed:
None
WARNING
37
38