User manual

Managing Network Interfaces
Rev 1.1.0 User Manual 37
Interferer Handling Mode Select between Dynamic or Static - Low,
Moderate, and High. Each selection
requires a Reboot to take effect. See
Setting the Operational Channel section
on page 38.
Dynamic Mode: In this mode, the
AP Automatically adapts to the
interference condition. Sensitivity is
decreased (CS and ED) when high
interference level is detected
Static - Low Interference: Static
configuration (Dynamic Handling is
Disabled) with maximal sensitivity
configuration (maximal range). To be
used in non-interfered environment
Static - Moderate Interference:
Static configuration with mild
degraded sensitivity configuration,
for moderate interfered environment
condition.
Static - High Interference: Static
configuration with significant
degraded sensitivity configurations,
for highly interfered environment.
Rates
Operational Rate The Operational Rate Set is the set of all of
the PHY rates (modulations) that the AP
uses for its regular operation.
Basic Rate The Basic Rate Set is the set of mandatory
PHY rates that the clients must support in
order to join this AP’s network.
Options
Apply Click to have your changes take effect
temporarily
Save (from the menu
bar)
Click to have your changes remain in
effect after a reboot
Cancel Click to clear your changes; this is only
possible if Apply or Save were not clicked
Table 4.3. Switched 802.11 b/g page
Field Description