Instruction manual

WBSn-2400 Quick Start Guide Page 9
Please also note the following:
Warnings
You must always install an external grounding wire. Make sure you have completed grounding
before you connect power to the WBSn-2400.
This is not a mid-span powered device. Do not attempt to daisy-chain PoE devices.
Note:
National Electrical Codes (NEC) Article 800 requires the use of an Agency Listed (UL/CSA)
Building Entrance Protector for all power and communications cables entering a building. Article
800 is intended to protect the building and occupants from fires caused by transient voltage
and current surges.
To connect to the data port:
1. Connect a grounding cable to the grounding terminal and tighten the grounding screw firmly. See
Grounding the Data protection device for a connection diagram.
2. Connect the other end of the cable to the nearest grounded metallic body.
3. Ensure that the power is turned off for the designated circuits.
4. Unscrew the plastic cap and the cap cover from the Wavion WBSn-2400.
5. Run a shielded Category 5 Ethernet cable (appropriate for outdoor use) through the cap.
6. Connect one end of the Category 5 cable to the OUT port of the Wavion PoE injector.
7. Connect the other end of the Category 5 Ethernet cable to the ETH port on the Wavion WBSn-2400.
Note: Use a shielded RJ45 8-pin modular plug to terminate the cables at the required length.
8. After connecting the Ethernet cable to the ETH port, close and firmly tighten the plastic cap. This
ensures perfect sealing and IP-67 compliance.
POE port RJ45 Pin Descriptions
Pin Signal Color Description
1 BI_DA+ Orange-White Bi-directional pair A +, POE GND
2 BI_DA- Orange Bi-directional pair A -, POE GND
3 BI_DB+ Green-White Bi-directional pair B +, POE +55V
4 BI_DC+ Blue Bi-directional pair C +, POE +55V
5 BI_DC- Blue-White Bi-directional pair C -, POE +55V
6 BI_DB- Green Bi-directional pair B -, POE +55V
7 BI_DD+ Brown-White Bi-directional pair D +, POE GND
8 BI_DD- Brown Bi-directional pair D -, POE GND
Accessing the Wavion Management Interface
The following procedure describes how to log in to the WBSn-2400 Wavion Management Interface, and from
there enter the Set-up Wizard, and further configuration information.
Note: The interface requires Java to work. Download the latest Java release from www.java.com.
1. In an internet browser, enter the Management IP address of the WBS unit in the URL navigation field
using secure HTTP protocol (https).
Default IP address: 192.168.1.1
Default mask: 255.255.255.0
Default gateway: 192.168.1.254
Note: Currently,
Microsoft Internet Explorer
and
Mozilla Firefox
browsers are supported.