Instruction manual
WBSn-2400 Quick Start Guide Page 6
Grounding best
practices, using a data
protection device
(continued)
Grounding outdoors injector by Network Protection Unit
Connecting Antennas (for WBSn-2400-O only)
Note: The antennas should only be connected once the installation procedure has been successfully
completed.
How to connect the
antennas:
Screw each of the three antennas into the three N-type connectors on the
WBSn-2400base station unit.
Warnings
• In order for the WBSn-2400 to work properly, all three antennas must be
connected.
• Only connect the unit to the power supply once all the antennas are
connected.
• Use caution when connecting the antennas. Undue haste can damage the
unit.
• Do not screw in the antenna when holding its top section, or you may
damage the antenna.
Antenna Sealing
The following procedure describes how to correctly seal the antennas against moisture.
Caution
• It is important to carefully read this procedure and perform all the steps, to
ensure maximal moisture protection.
• Use high quality sealing material to ensure IP-67 compliant protection
against dust and water.
How to seal the
antennas:
1. After the antenna is connected, use the supplied isolation tape to cover the N-
Type connectors and the lower part of the antennas.
2. Cut 18 cm of the attached splicing tape.
3. Stretch and wrap the tape in an even, half overlapping manner around the
antenna and N-Type connector. Cover this with a layer of vinyl plastic tape.
Safety instructions and information
Please ensure that you read and understand the following safety information. Ensure that you
carefully read and follow all instructions in this manual, and heed all warnings.
Warnings
It is illegal to modify the construction of this product. Modifying the operating
frequency or enhancing the transmit output power through the use of external
amplifiers or other equipment is specifically disallowed by the
"Telecommunications Act.
There is a risk of personal injury or death if the WBSn-2400 antennas are close to
electric power lines.
By nature of the outdoor installation, you may be exposed to hazardous
environments and high voltage. Use extreme caution when installing the system.