Preparing the installation site
Only experienced installation professionals who are familiar with local building and safety codes and are
licensed, wherever applicable, by the appropriate government regulatory authorities, should install outdoor
units and antennas.
Warnings
Do not modify the construction of this product. Modifying the operating frequency
or enhancing the transmit output power through the use of external amplifiers or
other equipment is illegal.
This device is for outdoor or indoor use on the condition that operation of this
device causes no harmful interference to authorized radio stations. This device
shall not influence aircraft security and/or interfere with legal communications. If
this device is found to cause interference, the operator of this equipment shall
cease operating this device immediately.
How to prepare the
site:
Ascertain the existence of potential posts or poles to which a base station
could be attached. Consider the axis of the post, its placement, and whether
extenders are required.
Follow the appropriate electrical and building codes to ensure safe and
durable wiring.
The length of the Ethernet cable connecting the unit to the network device
(PC, switch, router, and so on) should not exceed 100 meters. There is no
limitation on the length of the cable connecting the PoE to the unit, as long
as the combined length of the cables connecting the network device to the
PoE and the PoE to the unit does not exceed 100 meters.
Grounding best
practices, using a data
protection device
1. Position the protection device as close to the building entrance as possible.
2. Attach a 10 AWG grounding cable to the ground point on the data protection
device.
3. Attach the other end of the grounding cable to the grounding bar of the
building.
Grounding indoors injector by Network Protection Unit