3. Create the trunked VLAN on disabled SSID.
The VLAN appearing at the CPE side should be configured to appear at the WBS side. The way
of doing that is by creating a new SSID with the required VLAN without enabling the SSID (the
VLAN must be enabled). In this way, the VLAN will exist in the Ethernet interface of the WBS,
but not in the air interface.
4. Connect CPE
Set the CPE to work as WDS station. All the VLAN frames at the CPE side will be encapsulated
and transmitted to the WBS side. There they are de-capsulated and sent through the specific
VLAN.
5. Check Status
The Backhaul CPE status can be checked through the “Connected Backhauls” page. Detailed
information is displayed when the underlined values are selected. The details are identical as an
associated CPE. Please refer to Viewing Associated Stations section for more information