User manual
Upgrading the System Software
107 Wavion
Verify IP connectivity to the management IP.
In order to verify the connection, PING the unit's IP address and verify that PING replies are
being received.
Note: Management traffic may be VLAN tagged.
It is recommended to perform prior to upgrading procedure, software verification and to verify
that we have the appropriate file with extension *.wj on your computer.
It is recommended to save unit configuration file prior to upgrading (see user manual for
details).
Upload firmware file
• Verify IP connectivity to the management IP
• Verify that the IP address of the unit is known. The default IP address of a unit leaving
Wavion facility is 192.168.1.1/24 with user name: admin pass: admin
• Change the IP address of the PC to be in the same subnet as the unit. For example if the
units IP address is 192.168.1.1 the IP address of the PC may be 192.168.1.10
• Connect the PC Ethernet port to the WBS-2400 Unit Ethernet port using a straight or
cross Ethernet cable).
• Use any Web Browser and type unit IP address (Default: http://192.168.1.1 )
• Access the System upgrade area.
• Select the Unit that needs to be upgraded and choose “System Software” menu under
“System” menu.